2011
DOI: 10.4103/0974-8520.96136
|View full text |Cite
|
Sign up to set email alerts
|

Physico-chemical analysis of a Herbo-mineral compound Mehamudgara vati - A pilot study

Abstract: Efforts have been made to lay down analytical standards for Mehamudgara vati (MMV), which were not found reported till date. Weight variation showed that 90% tablets of MV manufactured in the Gujarat Ayurved University Pharmacy were within acceptable range (323 mg ± 10%), pH 4.58, and disintegration time 17 min, whereas hardness was 1.25 kg/cm2. Loss on drying was found to be 9.3% w/w, acid insoluble ash was 0.9 %w/w, water soluble extract was 24.06% w/w and methanol soluble extract 14.1% w/w. Determination of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 2 publications
0
6
0
Order By: Relevance
“…The prepared Vati is found to have 495mg average weight ± 10% range of weight variation is acceptable. [5] Bioavailability of the medicine is depending on harness and disintegration. The Kaidaryadi Ghanavati found to be having hardness of 10 kg/cm.…”
Section: Discussionmentioning
confidence: 99%
“…The prepared Vati is found to have 495mg average weight ± 10% range of weight variation is acceptable. [5] Bioavailability of the medicine is depending on harness and disintegration. The Kaidaryadi Ghanavati found to be having hardness of 10 kg/cm.…”
Section: Discussionmentioning
confidence: 99%
“…This is also a good indicator to justify the identity of the product. The high water-soluble value can be due to the presence of various herbal drugs in the herbomineral product indicating the solubility of formulation in water (10). It also signifies the presence of phytochemicals such as sugar and inorganic compounds.…”
Section: Discussionmentioning
confidence: 99%
“…16 . (4) Determination of Loss on Drying: The samples are taken in china dish and placed in hot air oven and the weight is observed in every half an hour till same weight is observed, weight loss is due to the removal of water and volatile ingredients 20 .…”
Section: Characterization Of Bhasma Particlesmentioning
confidence: 99%
“…(5) Determination of pH: Aqueous solution is prepared and measurements are carried out at 25 ºC using pH meter 20 .…”
Section: Classicalmentioning
confidence: 99%