2000
DOI: 10.1016/s1051-0443(07)61620-0
|View full text |Cite
|
Sign up to set email alerts
|

Physical Properties of Endovascular Stents: An Experimental Comparison

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
118
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 187 publications
(120 citation statements)
references
References 35 publications
2
118
0
Order By: Relevance
“…Therefore, the design and the material of the carotid stents take on considerable importance in achieving a good long-term clinical outcome. Requirements placed on the stent are reliable plaque coverage, accompanied by good wall adjustment through high flexibility and radial force [15,16]. The importance of these requirements on a carotid stent is highlighted by a study that shows that most neurological complications do not occur until the post-procedural phase [17].…”
mentioning
confidence: 99%
“…Therefore, the design and the material of the carotid stents take on considerable importance in achieving a good long-term clinical outcome. Requirements placed on the stent are reliable plaque coverage, accompanied by good wall adjustment through high flexibility and radial force [15,16]. The importance of these requirements on a carotid stent is highlighted by a study that shows that most neurological complications do not occur until the post-procedural phase [17].…”
mentioning
confidence: 99%
“…There have been many studies that have evaluated mechanical properties of a stent. (Duda et al, 2000) reported that the important properties of a stent include acceptable weight, stiffness in its radial direction, ease of insertion into the blood vessel, and radiation transmittance capability. They then proposed a method to evaluate stent and its performances.…”
Section: Methods To Select Stent Suitable For Clinical Manifestation Bmentioning
confidence: 99%
“…The stent stiffness in radial direction was measured by using the radial compression test machine designed by reference to the method proposed by (Duda et al, 2000). A stent is mounted on the polytetrafluoroethylene stage with slit and wrapped in a sheet.…”
Section: Radial Compression Test and Stent Stiffness In Radial Directionmentioning
confidence: 99%
“…3,[14][15][16][17][18][19] One of the most important factors is RF because it expands and maintains the lumen at the stricture segment of the bile duct after the SEMS are deployed. The force can be influenced by the wire diameter, cell size (which depends on how close the wire is woven), and the wire-knitting method (braided, specially braided, or laser cut …”
Section: Mechanical Properties Ofsemsmentioning
confidence: 99%