2020
DOI: 10.1109/tap.2019.2963229
|View full text |Cite
|
Sign up to set email alerts
|

Physical Insight Unveils New Imaging Capabilities of Orthogonality Sampling Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
23
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 34 publications
(29 citation statements)
references
References 34 publications
1
23
0
Order By: Relevance
“…The OSM provides an approximation of the geometrical properties of the unknown targets by plotting an indicator function I(r p ) on an arbitrary grid of points r p = (x p , y p ) sampling the imaging domain Ω [12].…”
Section: A Qualitative Inversion: Orthogonality Sampling Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The OSM provides an approximation of the geometrical properties of the unknown targets by plotting an indicator function I(r p ) on an arbitrary grid of points r p = (x p , y p ) sampling the imaging domain Ω [12].…”
Section: A Qualitative Inversion: Orthogonality Sampling Methodsmentioning
confidence: 99%
“…As far as the qualitative imaging approach is concerned, the proposed processing framework exploits the orthogonality sampling method (OSM) [12]. In OSM, the evaluation of the indicator function does not require the explicit solution of an inverse problem, so that there is no need for determining a regularization parameter.…”
Section: Introductionmentioning
confidence: 99%
“…In the cases presented in this paper, ߳ ሺ߱ሻ is taken as the Debye model of the external coupling medium, which has similar properties to the internal head tissues. It is worth noting that the SAFT formula in (6) is similar to the orthogonality sampling method (OSM), introduced in [32] and recently physically interpreted in [33], [34]. Basically, in the OSM, the phase shifting term in the SAFT indicator function (6) is replaced by another phase factor, which is related to the far field pattern of the Green's function.…”
Section: Construction Of An Approximate Qualitative Mapmentioning
confidence: 99%
“…However, to retrieve the dielectric profile of the target, most of standard CNN-based architectures do not work directly with the measurements of scattered fields collected by the receiving antennas, but require a preliminary image retrieved by other techniques [41], [42], [45], [51], [54]. This image may be obtained with other inverse-scattering approaches, e.g., orthogonality sampling method (OSM) [55], back propagation (BP) [56] and direct sampling method [57].…”
Section: Introductionmentioning
confidence: 99%