2010
DOI: 10.1016/j.solener.2010.04.011
|View full text |Cite
|
Sign up to set email alerts
|

Photovoltaic solar system connected to the electric power grid operating as active power generator and reactive power compensator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
28
0
2

Year Published

2010
2010
2021
2021

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 113 publications
(36 citation statements)
references
References 15 publications
1
28
0
2
Order By: Relevance
“…Thus, a solar PV power generation system including a shunt active filtering function connected to the grid would be very useful for the improvement of power quality for both costumers and utility operators [14][15][16][17][18][19][20][21][22][23]. The shunt active filtering functionality can be achieved only by changing the control algorithm of the inverter.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, a solar PV power generation system including a shunt active filtering function connected to the grid would be very useful for the improvement of power quality for both costumers and utility operators [14][15][16][17][18][19][20][21][22][23]. The shunt active filtering functionality can be achieved only by changing the control algorithm of the inverter.…”
Section: Introductionmentioning
confidence: 99%
“…• 22 trabalhos têm o objetivo específico de modelar inversores com a funcionalidade de compensação de reativos incorporada e demonstrar sua viabilidade técnica (HASSAINE et al, 2014;CHANG et al, 2014;RESHMA;RAJESH, 2013;MARTI et al, 2013;BELAIDI et al, 2013;NOROOZIAN;GHAREHPETIAN, 2013;LI et al, 2012;HAMZAOUI;BOUCHAFAA;HADJAMMAR, 2011;TURITSYN et al, 2011;LIU et al, 2011;SEO et al, 2009;ALBUQUERQUE et al, 2010;CAGNANO et al, 2011;TSENGENES;ADAMIDIS, 2011;TURITSYN et al, 2010;GHARAKHANY;MOHAMADIAN;VARJANI, 2009;CHUNLING et al, 2009;HAMROUNI;JRAIDI;CHÉRIF, 2008;HASSAINE et al, 2009;LIBO;ZHENGMING;JIANZHENG, 2007;YU;PAN;XIANG, 2005;BARBOSA et al, 1998;KIM;YOO;SONG, 1996);…”
Section: Síntese Da Revisão Bibliográficaunclassified
“…On the other hand, depending on time and weather variability, the simultaneous occurrence of excess intermittent renewable generation (i.e., wind and solar PV) and low demand would lead to loss of voltage regulation along with unexpected voltage-rise on the feeders due to reverse power flows [102]. As a fast response device, the inverter-based PV unit is allowed to inject or absorb reactive power to stabilize load voltages as per the new German grid code [103] while supplying energy as a primary task [101,104]. Other technologies such as synchronous machines used in biomass power plants, and Doubly-Fed Induction Generators (DFIGs) or full converter synchronous machines employed in wind farms are also capable of controlling reactive power while supplying active power [105].…”
Section: Grid Codes For Dg Integrationmentioning
confidence: 99%
“…As described in Section 3.3.4, the inverter-based PV technology [101,104], which is capable of delivering active power and exporting or consuming reactive power, is adopted in this study. The relationship between the active and reactive power of a PV unit at bus k ( k PV P and k PV Q ) can be expressed as follows [24]:…”
Section: Solar Pv Modellingmentioning
confidence: 99%
See 1 more Smart Citation