Photoplethysmography 2022
DOI: 10.1016/b978-0-12-823374-0.00015-3
|View full text |Cite
|
Sign up to set email alerts
|

Photoplethysmography signal processing and synthesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
21
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 28 publications
(21 citation statements)
references
References 191 publications
0
21
0
Order By: Relevance
“…For an analysis of morphological features of individual PPG pulse waves, a relatively high sampling frequency f S (higher than 500 Hz) is required [ 25 ]. On the other hand, in continuous long-term screening and monitoring, sampling at lower frequencies may be used, for example, 128 Hz in a wrist-based wearable device for atrial fibrillation detection [ 26 ].…”
Section: Methodsmentioning
confidence: 99%
“…For an analysis of morphological features of individual PPG pulse waves, a relatively high sampling frequency f S (higher than 500 Hz) is required [ 25 ]. On the other hand, in continuous long-term screening and monitoring, sampling at lower frequencies may be used, for example, 128 Hz in a wrist-based wearable device for atrial fibrillation detection [ 26 ].…”
Section: Methodsmentioning
confidence: 99%
“…Several approaches have been proposed, including statistical analysis of pulse wave shape [ 56 ], assessing the level of perfusion through the perfusion index (the ratio of the amplitude of the pulsatile component of the PPG to its baseline) [ 56 ], assessing the similarity of successive pulse wave shapes using template matching [ 86 ] or dynamic time warping [ 87 ], and deep learning [ 88 ]. For further details of techniques, see [ 10 ]. Typically, signal segments are deemed to be either high or low quality through the use of empirical thresholds.…”
Section: Ppg Signal Processingmentioning
confidence: 99%
“…Derivatives are typically derived from the PPG after eliminating high-frequency noise, which can otherwise greatly obscure the derivatives. This low-pass filtering is a compromise between retaining the original signal features and increasing robustness to noise [ 10 ].…”
Section: Ppg Signal Processingmentioning
confidence: 99%
“…The rising edge from onset to systolic represents increasing pressure in the artery, as measured in the arterial blood pressure (ABP) waveform. The dicrotic notch and diastolic peaks are wave reflections of the periphery, influenced by arterial stiffness or vascular resistance and compliance ( 15 ). If onset is related to the beginning of systolic ejection, then diastolic denotes the end of ejection as the aortic valve closed ( 16 ).…”
Section: Ppg and Ppg Derivativesmentioning
confidence: 99%
“…If onset is related to the beginning of systolic ejection, then diastolic denotes the end of ejection as the aortic valve closed ( 16 ). As people start aging, the notch and diastolic tend to disappear in the signal ( 15 ).…”
Section: Ppg and Ppg Derivativesmentioning
confidence: 99%