2016
DOI: 10.1016/j.ejmp.2015.09.015
|View full text |Cite
|
Sign up to set email alerts
|

Photon beam quality correction factors for the NE2571A and NE2581A thimble ionization chambers using PENELOPE

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…Monte Carlo simulations have been performed using the PENELOPE/ penEasy system [15,16] versions 2014 (PENELOPE) and 2018-04-30beta (penEasy), which has been extensively tested for dosimetry problems relevant for the present work [7,17,21,18]. The penEasy tally named 'energy deposition' was used to obtain the energy absorbed in the relevant spatial regions.…”
Section: Monte Carlo Simulationsmentioning
confidence: 99%
“…Monte Carlo simulations have been performed using the PENELOPE/ penEasy system [15,16] versions 2014 (PENELOPE) and 2018-04-30beta (penEasy), which has been extensively tested for dosimetry problems relevant for the present work [7,17,21,18]. The penEasy tally named 'energy deposition' was used to obtain the energy absorbed in the relevant spatial regions.…”
Section: Monte Carlo Simulationsmentioning
confidence: 99%
“…Details of the other two chambers considered, the NE2571A and the NE2581A, were provided by the manufacturer and are described in the work by Erazo and Lallena [15]. These are Farmer-type chambers with sensitive volumes of 0.69 and 0.56 cm 3 , respectively.…”
Section: Ionization Chambersmentioning
confidence: 99%
“…The simulations performed in the present work were carried out in a way similar to those of previous works [13][14][15], following the prescription of Sempau and Andreo [26] for the optimal values of the PENELOPE tracking parameters to simulate ionization chambers. Specifically, we used C 1 = C 2 = 0.02 for all materials of the ionization chamber and a water volume extending 2 cm around it.…”
Section: Monte Carlo Simulationsmentioning
confidence: 99%
See 1 more Smart Citation
“…This clarifies that the gradient corrections were implicitly calculated and included. Two studies by Erazo 13,14 provide Monte Carlo calculated data for cylindrical chambers and other studies 15,16 focused on the beam quality factor kQ${k}_{Q\ }$calculated for parallel‐plate chambers. The systematic uncertainties in calculated beam quality conversion factors for the NE2571 chambers are less than 1.2% using conservative assumptions 11 .…”
Section: Introductionmentioning
confidence: 99%