Photon attenuation in computed tomography

Abstract: The analysis and understanding of results of computed tomography (CT) require an understanding of photon attenuation in matter. The high sensitivity and resolution of these devices coupled with the use of a polychromatic photon source require a level and breadth of understanding about photon attenuation not usually required in any particular subspecialty of radiological physics. With this goal in mind, a discussion of narrow-beam photon attenuation in matter is given and related to those problems currently und… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
123
0
5

Year Published

1989
1989
2020
2020

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 264 publications
(134 citation statements)
references
References 0 publications
2
123
0
5
Order By: Relevance
“…The response of CT scanners to biological materials with X-ray attenuation near that of water is fairly well known (McCullough, 1975) and shows that a density increase of 0.01 g/cm 3 corresponds to an increase of 10 units in the CT value. Device response to denser materials and those of different composition, such as soils and sediments, however, is less certain (e.g., Petrovic et al, 1982;Soh et al, 1993).…”
Section: Relationships Of Ct Values Bulk Density and Water Contentmentioning
confidence: 99%
“…The response of CT scanners to biological materials with X-ray attenuation near that of water is fairly well known (McCullough, 1975) and shows that a density increase of 0.01 g/cm 3 corresponds to an increase of 10 units in the CT value. Device response to denser materials and those of different composition, such as soils and sediments, however, is less certain (e.g., Petrovic et al, 1982;Soh et al, 1993).…”
Section: Relationships Of Ct Values Bulk Density and Water Contentmentioning
confidence: 99%
“…As shown in McCullough [10] an exponent of 3.8 is only representative of the Zdependence of the photoelectric absorption, and will consistently over-estimate the Z eff for other materials with high-Z constituents. Typical HME are dominated more by Compton than photoelectric absorption, and an optimal compromise would use a smaller exponent.…”
Section: The Use Of the Zeff Equation Is Inherently Problematicmentioning
confidence: 99%
“…If higher-Z components are present in the materials, it becomes very difficult to fit Equation 2 to materials of interest. For example, McCullough [10] warns that:…”
Section: Equationmentioning
confidence: 99%
See 1 more Smart Citation
“…
Computed tomography (CT) is a non-destructive technology that produces an image of an internal slice through a sample via the reconstruction of a matrix of X-ray attenuation coefficients [1,2]. An imaged slice can be divided into ann x n matrix of voxels (volume elements).
…”
mentioning
confidence: 99%