1988
DOI: 10.1016/1010-6030(88)85010-x
|View full text |Cite
|
Sign up to set email alerts
|

Photoinitiated bulk polymerization of lauryl acrylate by N-acetyl-4-nitro-1-naphthylamine in the presence of N,N-dimethylaniline

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0
1

Year Published

1996
1996
2013
2013

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 41 publications
(18 citation statements)
references
References 14 publications
0
17
0
1
Order By: Relevance
“…A detailed description of the photo-differential scanning calorimeter (PDSC) can be found in previous publications. 16,17 In our current work the twin-branch¯exible light guides (each of 50 cm length) were terminated with a ferrule connector which was plugged into the lightguide socket of a cold light source (Schott KL-1500, Germany). This irradiation source permitted the direct regulation of the light intensity in graduated stages by means of a brightness control.…”
Section: Measurement Of Light Absorption and Photopolymerization Kinementioning
confidence: 99%
See 1 more Smart Citation
“…A detailed description of the photo-differential scanning calorimeter (PDSC) can be found in previous publications. 16,17 In our current work the twin-branch¯exible light guides (each of 50 cm length) were terminated with a ferrule connector which was plugged into the lightguide socket of a cold light source (Schott KL-1500, Germany). This irradiation source permitted the direct regulation of the light intensity in graduated stages by means of a brightness control.…”
Section: Measurement Of Light Absorption and Photopolymerization Kinementioning
confidence: 99%
“…16,17 All polymerizations were carried out in bulk at 40°C. Samples of about 60 mg were accurately weighed, and spread as a layer over the base of 6.5 mm diameter aluminium DSC standard pans.…”
Section: Measurement Of Light Absorption and Photopolymerization Kinementioning
confidence: 99%
“…A detailed description of the modified differential calorimeter can be found in previous papers. [10,11] In our current work the twin-branch flexible light guides (each 50 cm long) are terminated with a ferrule connector, which is plugged into the light guide socket of a cold light source (Schott KL-1500). This irradiation source allows the direct regulation of the light intensity in graduate stages by means of a brightness control.…”
Section: Steady-state Photolysis Of Pm567mentioning
confidence: 99%
“…As determinações calorimétricas são feitas usando sistemas como o mostrado na Figura 10, que consiste em um calorímetro comercial modificado, [52,53] incorporando um acessório que permite a irradiação da amostra fotopolimerizável simultaneamente à obtenção das curvas exotérmicas.…”
Section: Calorimetriaunclassified