2022
DOI: 10.1039/d2an00522k
|View full text |Cite
|
Sign up to set email alerts
|

Photoelectrochemical sandwich immunoassay of CYFRA21-1 based on In2O3/WO3type-II heterojunction and CdS quantum dots-polydopamine nanospheres labeling

Abstract: Using an In2O3/WO3 type-II heterojunction modified fluorine-doped tin oxide (FTO) electrode as the photoanode and CdS quantum dots (QDs)-polydopamine nanospheres (PDA NSs) as the secondary antibody (Ab2) labeling, the photoelectrochemistry...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 59 publications
0
4
0
Order By: Relevance
“…The biosensor showed ideal linearity from 0.5 pg mL −1 to 10 ng mL −1 , LOD of 0.29 pg mL −1 , good stability, and desirable selectivity under optimal conditions. Liu et al [62] provided an In 2 O 3 /WO 3 type-II heterojunction-modified fluorine-doped tin oxide electrode as the photoanode and CdS QDs-polydopamine nanospheres as the secondary antibody label for PECI to measure the concentration of lung cancer marker CYFRA21-1 (Figure 8c). As expected, a signal-enhanced immunosensor can be achieved by amplifying the photocurrent signal through the formation of a sandwich immunostructure, and the photocurrent was linear with the common logarithm of CYFRA21-1 ranging from 100 fg mL −1 to 50 ng mL −1 , with a LOD of 56 fg mL −1 .…”
Section: Photoelectrochemical Immunoassaysmentioning
confidence: 99%
See 2 more Smart Citations
“…The biosensor showed ideal linearity from 0.5 pg mL −1 to 10 ng mL −1 , LOD of 0.29 pg mL −1 , good stability, and desirable selectivity under optimal conditions. Liu et al [62] provided an In 2 O 3 /WO 3 type-II heterojunction-modified fluorine-doped tin oxide electrode as the photoanode and CdS QDs-polydopamine nanospheres as the secondary antibody label for PECI to measure the concentration of lung cancer marker CYFRA21-1 (Figure 8c). As expected, a signal-enhanced immunosensor can be achieved by amplifying the photocurrent signal through the formation of a sandwich immunostructure, and the photocurrent was linear with the common logarithm of CYFRA21-1 ranging from 100 fg mL −1 to 50 ng mL −1 , with a LOD of 56 fg mL −1 .…”
Section: Photoelectrochemical Immunoassaysmentioning
confidence: 99%
“…[60] Copyright 2019, American Chemical Society. The sensitivity of the PECI sensor was improved by copper in situ deposition signal amplification (b) [61] , heterojunction modification (c) [62] , and energy level matching principles (d) [63] . Copyright 2019, Royal Society of Chemistry.…”
Section: Fluorescent Immunoassaysmentioning
confidence: 99%
See 1 more Smart Citation
“…[9][10][11][12][13] Among these techniques, photoelectrochemical (PEC) methods with the merits of costefficiency, easy operation, rapid analysis, and low background values have attracted more and more attention. [14][15][16][17][18] For example, Xu et al proposed a localized surface plasmon resonance and piezoelectric effect-based co-enhanced PEC sensing strategy for accurate monitoring of prostate-specific antigens. 19 Song's group designed a switchable multiplex PEC biosensor for the simultaneous detection of Alzheimer's disease-related amyloid-beta 42 and amyloid-beta 40.…”
Section: Introductionmentioning
confidence: 99%