1993
DOI: 10.1016/0021-9673(93)87019-i
|View full text |Cite
|
Sign up to set email alerts
|

Photodiode array detection for elucidation of the structure of phenolic compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0

Year Published

1996
1996
2008
2008

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 52 publications
(24 citation statements)
references
References 8 publications
0
24
0
Order By: Relevance
“…The effect of substituents on the UV spectrum depends more on their position and interaction than on their chemical nature. The ortho and meta positions give bathochromic shifts of the UV maxima at longer wavelengths [109]. In addition, a symmetrical UV spectrum, relating to the maximum at 280 nm, is characteristic for a homogeneous procyanidin polymer [110], whereas symmetry is disturbed in mixed procyanidin-prodelphinidin polymers.…”
Section: Uv and Dadmentioning
confidence: 99%
“…The effect of substituents on the UV spectrum depends more on their position and interaction than on their chemical nature. The ortho and meta positions give bathochromic shifts of the UV maxima at longer wavelengths [109]. In addition, a symmetrical UV spectrum, relating to the maximum at 280 nm, is characteristic for a homogeneous procyanidin polymer [110], whereas symmetry is disturbed in mixed procyanidin-prodelphinidin polymers.…”
Section: Uv and Dadmentioning
confidence: 99%
“…Chromatographic peaks were identified by comparing retention times, UV spectra and data of UV spectral parameters (Bartolome´et al, 1993(Bartolome´et al, , 1996, with those of standards, or those of previously purified and identified procyanidins (Pe´rez-Ilzarbe et al, 1992), recorded in the same chromatographic conditions with the PAD.…”
Section: Identification and Quantification Of The Compoundsmentioning
confidence: 99%
“…Chromatographic peaks were identified by comparison of the retention times, UV spectra and data of UV spectral parameters 28,29 with those of standards. The standards gallic, protocatechuic, phydroxybenzoic, vanillic, trans-p-coumaric and transferulic acids, tyrosol and hydroxymethylfurfuraldehyde were from Aldrich Chimie (Munich, Germany) and the standards quercetin 3-O-galactoside, quercetin 3-O-glucoside and quercetin were from Extrasynthese (Genay, France).…”
Section: Identification and Quantification Of Compoundsmentioning
confidence: 99%