2013
DOI: 10.1021/es403472e
|View full text |Cite
|
Sign up to set email alerts
|

Photocatalytic Degradation of Water Contaminants in Multiple Photoreactors and Evaluation of Reaction Kinetic Constants Independent of Photon Absorption, Irradiance, Reactor Geometry, and Hydrodynamics

Abstract: The literature on photocatalytic oxidation of water pollutants often reports reaction kinetic constants, which cannot be unraveled from photoreactor type and experimental conditions. This study addresses this challenging aspect by presenting a general and simple methodology for the evaluation of fundamental "intrinsic" reaction kinetic constants of photocatalytic degradation of water contaminants, which are independent of photoreactor type, catalyst concentration, irradiance levels, and hydrodynamics. The degr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
45
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
7
1
1

Relationship

3
6

Authors

Journals

citations
Cited by 72 publications
(48 citation statements)
references
References 37 publications
0
45
0
Order By: Relevance
“…This fluid was added to a mixture of 18 mL stock solution with 25 mL ethanol at 70 °C. After cooling to room temperature, the liquid paste was immobilized on an ITO glass (area 2.25 cm 2 ) by doctor-blade technique as reported elsewhere [22,23]. After coating the films were kept in a clean box for 15 min to relax surface irregularities and the residual mechanical stress of the coating.…”
Section: Synthesis Of Nanoparticulate Tio 2 Photoanodementioning
confidence: 99%
“…This fluid was added to a mixture of 18 mL stock solution with 25 mL ethanol at 70 °C. After cooling to room temperature, the liquid paste was immobilized on an ITO glass (area 2.25 cm 2 ) by doctor-blade technique as reported elsewhere [22,23]. After coating the films were kept in a clean box for 15 min to relax surface irregularities and the residual mechanical stress of the coating.…”
Section: Synthesis Of Nanoparticulate Tio 2 Photoanodementioning
confidence: 99%
“…When it is used to measure the irradiance from blacklight UV-A lamps the readings should be multiplied by a factor equal to 1.54 to ascertain the true value. This correction was elaborated previously (Grčić and Li Puma 2013). Used blacklight UV-A lamps were considered as sources of pseudo-monochromatic irradiation (365 nm) and calculations were performed accordingly.…”
Section: Irradiation Measurementsmentioning
confidence: 99%
“…Typically, the interpretation of the experimental results is based on t 30w (19), the treatment time (20), the incident radiation within the reactor, and the photon flux absorbed by the catalyst. However, these parameters interact and yield erroneous conclusions, which is impractical given that the reactor is comprised of illuminated and non-illuminated areas.…”
Section: Mass Balance In the Dark Zonementioning
confidence: 99%