2021
DOI: 10.1016/j.toxicon.2021.05.009
|View full text |Cite
|
Sign up to set email alerts
|

Photobiomodulation induces murine macrophages polarization toward M2 phenotype

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…PBM (945 nm, 3 J/cm 2 ) significantly reduced the gene expressions of IL-6 and TNF-α in isolated macrophages incubated with Bothrops jararacussu venom (BjV). Furthermore, this study indicated that PBM increased the polarization of macrophages to the M2 phenotype, repairing tissue and suppressing inflammation [ 102 ]. Liao et al also reported that PBM inhibited the inflammatory response through the macrophage M2 polarization in human THP-1 monocyte cells, human primary macrophages, and mice intraperitoneal macrophages, which was regulated by mitochondrial respiratory gene citrate synthase [ 103 ].…”
Section: Pbm Overviewmentioning
confidence: 99%
“…PBM (945 nm, 3 J/cm 2 ) significantly reduced the gene expressions of IL-6 and TNF-α in isolated macrophages incubated with Bothrops jararacussu venom (BjV). Furthermore, this study indicated that PBM increased the polarization of macrophages to the M2 phenotype, repairing tissue and suppressing inflammation [ 102 ]. Liao et al also reported that PBM inhibited the inflammatory response through the macrophage M2 polarization in human THP-1 monocyte cells, human primary macrophages, and mice intraperitoneal macrophages, which was regulated by mitochondrial respiratory gene citrate synthase [ 103 ].…”
Section: Pbm Overviewmentioning
confidence: 99%
“…LED (Light Emitting Diode) Treatment. Cells were irradiated with a 945 nm infrared LED device (model Super Bright LEDs, Inc., St. Louis, MO, USA) immediately upon addition of the venom or toxin in the culture and LED was applied with direct contact to the bottom of the well plate in a continuous mode for 30 s [14][15][16]. The experiments were conducted in an environment with partial obscurity to not suffer interference from external light.…”
Section: Endotoxin Quantificationmentioning
confidence: 99%
“…The output power of the LED equipment was measured using the Laser Check power meter (MM Optics, São Carlos, Brazil). The LED parameters, low enough to avoid any thermal effect, were chosen based on previous studies [11,[14][15][16]. The experimental parameters for the LED are presented in Table 1.…”
Section: Endotoxin Quantificationmentioning
confidence: 99%
See 2 more Smart Citations