2019
DOI: 10.1007/s13399-019-00372-x
|View full text |Cite
|
Sign up to set email alerts
|

Photoacoustic spectroscopy for detection of N2O emitted from combustion of diesel/beef tallow biodiesel/sugarcane diesel and diesel/beef tallow biodiesel blends

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 46 publications
0
6
0
Order By: Relevance
“…Nitrogen Dioxide (NO 2 ) LD [108][109][110][111][112] Multimode LD [113] LED [114][115][116][117][118] Nitric Oxide (N 2 O) QCL [112,119] OPO [120] Nitrogen oxide (NO) QCL [121] LD [122] Ammonia (NH 3 ) QCL [123][124][125] CO 2 laser [126,127] LD [128] Carbon Dioxide (CO 2 ) QCL [129] CO 2 laser [130] LD [131][132][133][134] OPO [135] Table 2. Cont.…”
Section: Target Gas (Es) Light Source Referencementioning
confidence: 99%
“…Nitrogen Dioxide (NO 2 ) LD [108][109][110][111][112] Multimode LD [113] LED [114][115][116][117][118] Nitric Oxide (N 2 O) QCL [112,119] OPO [120] Nitrogen oxide (NO) QCL [121] LD [122] Ammonia (NH 3 ) QCL [123][124][125] CO 2 laser [126,127] LD [128] Carbon Dioxide (CO 2 ) QCL [129] CO 2 laser [130] LD [131][132][133][134] OPO [135] Table 2. Cont.…”
Section: Target Gas (Es) Light Source Referencementioning
confidence: 99%
“…Based on these advantages, PAS gas detection technology has been applied to medical diagnosis, [10][11][12][13][14][15] industrial production, [16][17][18] environmental monitoring, and other fields. [19][20][21] Firstly, this paper introduces the basic principle of PAS gas detection technology. Secondly, the principle and application of different types of photoacoustic cells for gas detection are introduced.…”
Section: Introductionmentioning
confidence: 99%
“…Based on these advantages, PAS gas detection technology has been applied to medical diagnosis, 1015 industrial production, 1618 environmental monitoring, and other fields. 1921…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, it is an indirect measurement method without background signal interference. Because of these advantages, photoacoustic spectroscopy gas detection technology is widely used in medical, industrial production [ 21 , 22 , 23 ], environmental, [ 24 , 25 , 26 ], monitoring, and other fields [ 27 , 28 , 29 ].…”
Section: Introductionmentioning
confidence: 99%