Photons Plus Ultrasound: Imaging and Sensing 2017 2017
DOI: 10.1117/12.2253530
|View full text |Cite
|
Sign up to set email alerts
|

Photoacoustic measurements of red blood cell oxygen saturation in blood bags in situ

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 16 publications
0
4
0
Order By: Relevance
“…Further investigation is needed to analyze how strongly the RSPP correlates with other key morphometric and physiological storage lesion parameters; one such study has explored the quantitative overlap in RSPP and oxygen saturation (47). The IFC assay has the potential to fill this void in transfusion medicine research.…”
Section: Practical Implementationmentioning
confidence: 99%
See 1 more Smart Citation
“…Further investigation is needed to analyze how strongly the RSPP correlates with other key morphometric and physiological storage lesion parameters; one such study has explored the quantitative overlap in RSPP and oxygen saturation (47). The IFC assay has the potential to fill this void in transfusion medicine research.…”
Section: Practical Implementationmentioning
confidence: 99%
“…The RSPP, providing an estimate of the relative percentage of SECs, could be used as a quality metric or be part of the quality control program for stored RCC units. Further investigation is needed to analyze how strongly the RSPP correlates with other key morphometric and physiological storage lesion parameters; one such study has explored the quantitative overlap in RSPP and oxygen saturation (47). Studying its correlation with other storage lesion parameters could yield an estimate toward an absolute RSPP threshold that indicates viability for transfusion.…”
Section: Practical Implementationmentioning
confidence: 99%
“…The probes are coupled to a Nd:YAG laser which operates through an optical parametric oscillator generating tunable wavelengths between 680–970 nm at 20 Hz pulse repetition frequency, 6 ns pulse duration and a pulse energy of approximately 25–30 mJ . Both PA probes were illuminated at 750 nm and 850 nm to take advantage of the unique spectral signatures of oxyHb and deoxyHb for SO 2 calculations .…”
Section: Methodsmentioning
confidence: 99%
“…A custom‐built blood bag container was designed in‐house to measure the RCC units using water as a coupling medium for the detection of PA waves. To minimize prolonged exposure of RCC units to non‐refrigerated temperatures, the container was filled with cold deionized water.…”
Section: Methodsmentioning
confidence: 99%