2023
DOI: 10.1364/boe.503475
|View full text |Cite
|
Sign up to set email alerts
|

Photoacoustic imaging of visually evoked cortical and subcortical hemodynamic activity in mouse brain: feasibility study with piezoelectric and capacitive micromachined ultrasonic transducer (CMUT) arrays

Kai-Wei Chang,
Ermek Belekov,
Xueding Wang
et al.

Abstract: This study investigates the feasibility of capturing visually evoked hemodynamic responses in the mouse brain using photoacoustic tomography (PAT) and ultrasound (US) dual-modality imaging. A commercial piezoelectric transducer array and a capacitive micromachined ultrasonic transducer (CMUT) array were compared using a programmable PAT-US imaging system. The system resolution was measured by imaging phantoms. We also tested the ability of the system to capture visually evoked hemodynamic responses in the supe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 24 publications
0
3
0
Order By: Relevance
“…Figure 1(a) shows a schematic of our PACT system for real-time brain imaging. This system was used in our previous study 16 and is briefly described here. A neodymium-doped yttrium aluminum garnet laser-pumped optical parametric oscillator (Phocus MOBILE, OPOTEK Inc., Carlsbad, California, United States) was used as the excitation source, with a pulse duration of 5 to 7 ns, a pulse repetition rate of 10 Hz, and a pulse energy variation below 5%.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Figure 1(a) shows a schematic of our PACT system for real-time brain imaging. This system was used in our previous study 16 and is briefly described here. A neodymium-doped yttrium aluminum garnet laser-pumped optical parametric oscillator (Phocus MOBILE, OPOTEK Inc., Carlsbad, California, United States) was used as the excitation source, with a pulse duration of 5 to 7 ns, a pulse repetition rate of 10 Hz, and a pulse energy variation below 5%.…”
Section: Methodsmentioning
confidence: 99%
“… 12 PACT has successfully recorded visual responses in V1 cortex of mice 13 and rats 14 , 15 and more recently in the mouse SC. 16 In PACT-US parallel imaging, the PACT images are naturally co-registered with the US images as the transducer array acquires both simultaneously, thereby allowing the HR to be easily superimposed onto the brain anatomies revealed by US imaging.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation