2022
DOI: 10.1364/ol.452229
|View full text |Cite
|
Sign up to set email alerts
|

Photoacoustic computational ghost imaging

Abstract: Photoacoustic imaging with optical resolution usually requires a single-pixel raster scan. An alternative approach based on illumination with patterns obtained from a Hadamard matrix, measurement of the generated ultrasound wave with a single detector, followed by a reconstruction known from computational ghost imaging is demonstrated here. Since many pixels on the object are illuminated at the same time, thereby contributing to the recorded signal, this approach gives a better contrast-to-noise ratio compared… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 16 publications
0
3
0
Order By: Relevance
“…Secondly, single-pixel imaging may use exotic detectors whose 2D format with high specialization are impractical to manufacture. For instance, employing an ultrasonic transducer as detector, SPI has been used for photoacoustic imaging 66 , 67 . SPI paired with the photomultiplier tube has found applications in single-photon imaging 68 , for time-of-flight 3D imaging 69 , 70 , and imaging objects hidden from direct linefa-of-sight 71 .…”
Section: Discussionmentioning
confidence: 99%
“…Secondly, single-pixel imaging may use exotic detectors whose 2D format with high specialization are impractical to manufacture. For instance, employing an ultrasonic transducer as detector, SPI has been used for photoacoustic imaging 66 , 67 . SPI paired with the photomultiplier tube has found applications in single-photon imaging 68 , for time-of-flight 3D imaging 69 , 70 , and imaging objects hidden from direct linefa-of-sight 71 .…”
Section: Discussionmentioning
confidence: 99%
“…SPI combined with electrooptic detection has been used in terahertz (THz) imaging [7][8][9][10][11] . SPI implemented with ultrasonic transducers has found applications in photoacoustic imaging 12,13 .Recent years have witnessed the growing popularity of SPI owing to the hardware progress in spatial light modulators (SLMs) and software advances in image reconstruction. To date, the dominant SLM used in SPI is the digital micromirror device (DMD), which is capable of reconfigurable and nonmechanical display of mega-pixel patterns at refresh rates of up to 32 kHz 1 .…”
mentioning
confidence: 99%
“…SPI combined with electrooptic detection has been used in terahertz (THz) imaging [7][8][9][10][11] . SPI implemented with ultrasonic transducers has found applications in photoacoustic imaging 12,13 .…”
mentioning