Order By: Relevance
“…Therefore, longer electrolysis time lead to better effect of coagulation on phosphates. This result is supported by [14, 16, 17, 19] studies on removal of phosphate from drinking water by electrocoagulation process, Phosphorus Removal from wastewater in Johkasou Sewage treatment tank by electro-coagulation and phosphate removal efficiency electrocoagulation wastewater using iron and aluminum electrodes, respectively.…”
Section: Characterization Of Sludge and Aluminum Plate Electrodes Usisupporting
confidence: 65%
See 1 more Smart Citation
“…Therefore, longer electrolysis time lead to better effect of coagulation on phosphates. This result is supported by [14, 16, 17, 19] studies on removal of phosphate from drinking water by electrocoagulation process, Phosphorus Removal from wastewater in Johkasou Sewage treatment tank by electro-coagulation and phosphate removal efficiency electrocoagulation wastewater using iron and aluminum electrodes, respectively.…”
Section: Characterization Of Sludge and Aluminum Plate Electrodes Usisupporting
confidence: 65%
“…These results showed that the removal rates increased with the electrolysis time. Therefore, in the ranges of the test factors, the order of this electrolytic cell on the removal rate was depends on the electrolysis time and the number and nature of Al electrode systems [14].…”
Section: Resultsmentioning
confidence: 99%
“…É de adesão voluntária e, dependendo do seu momento de maior consumo, pode ser mais vantajoso o consumidor permanecer com a Tarifa Convencional. O adequado espaçamento entre os eletrodos evita a formação de resistência, o que tornaria necessário elevar a tensão de eletrólise, aumentando o consumo de energia (WANG et al, 2016).…”
Section: Consumo De Energia Elétricaunclassified
“…For Fe electrodes, the dried precipitate was red-brown due to the presence of the iron-pollutant and hydroxyl iron-pollutant in the precipitate formed (Wang et al, 2016). The same observation was obtained for the dried sludge when OFI mucilage was added, this could imply that the mucilage does not contribute to the pollutant adsorption mechanism of iron, thus in EC process with or without OFI mucilage addition, the formed precipitates could consist of iron-pollutants and -hydroxyl iron-pollutants.…”
Section: Analysis Of Generated Treatment Sludge From Ec Processmentioning
confidence: 99%
“…In the case of Al electrodes, the dried sludge was whitish grey; however, the gotten flocs are bulky within the sludge when the OFI mucilage was added in comparison with smaller flocs in the absence of mucilage. This can be due to the fact that OFI mucilage could engender double precipitation mechanism reaction (pollutant-Al-mucilage-OH and pollutant-Al(OH) -mucilage-OH), whereas in the absence of mucilage the precipitate formed consisted of pollutant-Al and pollutant-Al(OH) (Heidmann and Calmano, 2008;Wang et al, 2016;Adjeroud et al, 2018).…”
Section: Analysis Of Generated Treatment Sludge From Ec Processmentioning