1982
DOI: 10.1016/0002-9149(82)90014-5
|View full text |Cite
|
Sign up to set email alerts
|

Phase image characterization of ventricular contraction in left and right bundle branch block

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
24
0
1

Year Published

1985
1985
2021
2021

Publication Types

Select...
3
2
2

Relationship

1
6

Authors

Journals

citations
Cited by 77 publications
(25 citation statements)
references
References 9 publications
0
24
0
1
Order By: Relevance
“…Radionuclide ventriculography is a well established technique and it was the first one used in the evaluation of ventricular motility synchrony 13 . It is easy to use, fast, reproducible and it also allows evaluating the overall systolic There was a statistically significant difference in LVEF between groups 2 and 3.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Radionuclide ventriculography is a well established technique and it was the first one used in the evaluation of ventricular motility synchrony 13 . It is easy to use, fast, reproducible and it also allows evaluating the overall systolic There was a statistically significant difference in LVEF between groups 2 and 3.…”
Section: Discussionmentioning
confidence: 99%
“…Values above 40 ms are used by many services in the characterization of interand left intraventricular dyssynchrony through echocardiogram with tissue Doppler 30 . Our study evaluated left ventricular dyssynchrony in a different way than other studies that used RV [12][13][14][15][16]18 . We measured the width of LV phase histogram and not the standard deviation (SD).…”
Section: Brandão Et Al Ventricular Synchrony and Radionuclide Ventricmentioning
confidence: 99%
See 1 more Smart Citation
“…Each parameter was calculated from the first harmonic phase histogram in the ventricular ROIs: SDLVØ, SDRVØ, IVS (difference between mean LVS and RVS), LVS, and LVE are defined mathematically elsewhere (11,14,15).…”
Section: Definitionsmentioning
confidence: 99%
“…The sampling rate is sufficient to accurately measure LVEF (23), and temporal resolution is digitally enhanced and objectified by the generation of parametric images. The phase image has successfully tracked the sequence of ventricular wall motion in a variety of conduction abnormalities (15,16,(20)(21)(22)(23). The ability of planar ERNA phase analysis to assess myocardial synchrony is recognized (8,12,(20)(21)(22).…”
Section: Comparison Of Other Imaging Modalitiesmentioning
confidence: 99%