Abstract: The 3D indoor localization of low-cost standard mobile devices represents an important research topic. Since the implementation of ultra-wideband localization systems requires elaborated hardware, a localization concept based on phase-difference-of-arrival (PDOA) evaluation of narrow band communication signals at spatially distributed antennas is favorable in many applications. Typically, PDOA measurements are used to estimate the angle-of-arrival (AOA) at several receivers, which are then combined via multian… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
0
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 35 publications
(40 reference statements)
0
0
0
Order By: Relevance
“…This error mainly results from the dilution of precision, in particular in the z-direction, due to the disadvantageous spatial setup, as the entire measurement area had to be covered within line of sight of the receivers and multiple cameras. In [26], a positioning with a root-meansquared error in the outstanding sub-cm range is shown using the same localization system, where a robotic arm is used as a reference instead of cameras, which reveals the potential of the utilized localization system. Although no medical analysis is conducted in this measurement, it proves the feasibility of the proposed concept and its potential for an all-in-one gait analysis measurement system.…”
Section: Experimental Verificationmentioning
confidence: 95%
See 4 more Smart Citations
“…This error mainly results from the dilution of precision, in particular in the z-direction, due to the disadvantageous spatial setup, as the entire measurement area had to be covered within line of sight of the receivers and multiple cameras. In [26], a positioning with a root-meansquared error in the outstanding sub-cm range is shown using the same localization system, where a robotic arm is used as a reference instead of cameras, which reveals the potential of the utilized localization system. Although no medical analysis is conducted in this measurement, it proves the feasibility of the proposed concept and its potential for an all-in-one gait analysis measurement system.…”
Section: Experimental Verificationmentioning
confidence: 95%
“…to the spatially distributed antennas at the base stations. Utilizing a Holographic Extended Kalman Filter (HEKF), recently introduced by the authors in [25], [26], the beacons are localized by using the same RF signal as for data transmission. To this end, the HEKF recursively evaluats the relative phase of the RF signal by an Extended Kalman Filter (EKF).…”
Section: ) Small Size and Low Complexity Of The Transmittermentioning
confidence: 99%