2006
DOI: 10.1016/j.cmpb.2006.07.004
|View full text |Cite
|
Sign up to set email alerts
|

Phase coupling analysis of gastric pressure activity via wavelet packet based diagonal slice spectra

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…The calibrated pressure range was set at 5 kPa separations from 90 kPa to 100 kPa, and 2 kPa separations from 100 kPa to 120 kPa. This pressure range was physiologically reasonable within the intestinal tract, and the resolution was sufficient for cuff control and defecation-sensation feedback (15).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The calibrated pressure range was set at 5 kPa separations from 90 kPa to 100 kPa, and 2 kPa separations from 100 kPa to 120 kPa. This pressure range was physiologically reasonable within the intestinal tract, and the resolution was sufficient for cuff control and defecation-sensation feedback (15).…”
Section: Resultsmentioning
confidence: 99%
“…In addition, respiratory movements, electronic noise, and different frequency rectal movements also increased the detection difficulty. In future work, groups of pressure data under normal physiological conditions will be recorded indirectly and regularly, and processed using pattern recognition algorithms to extract the most relevant parameters (15, 16). Furthermore, the biocompatibility of the AASS and the thermal effects of the TET coils on surrounding tissues need to be further studied in long-term animal experiments.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The WPA is an extension of wavelet transform that offers a more abundant signal analysis [12][13][14]. In wavelet transform, a signal is divided into an approximation and a detail.…”
Section: Wpa Theorymentioning
confidence: 99%
“…The GI motility recordings were acquired by using a telemetric capsule (see Figure . 2), invented in the past few years for diagnosing gastrointestinal functional diseases (Wang et al, 2005;Yan et al, 2006Yan et al, , 2008Yan et al, , 2010. The four main components of the diagnosis system were: 1) A capsule, which was the first component that performed data acquisition of physiological parameters like pressure within the gastrointestinal tract under the normal physiological conditions, sent the data wirelessly to the next component, i.e., the in-vitro pocket data recorder.…”
Section: The Overview Of the Diagnosis Systemmentioning
confidence: 99%