2009
DOI: 10.1016/j.jchromb.2009.06.021
|View full text |Cite
|
Sign up to set email alerts
|

Pharmacokinetics of pefloxacin mesylate in human urine using capillary electrophoresis electrochemiluminescence detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2010
2010
2012
2012

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 23 publications
0
7
0
Order By: Relevance
“…-based electrochemiluminescence (ECL) has become an important detection method because it is simple and economical and has low background noise, high sensitivity, good selectivity and wide dynamic linear range (14,15). Recently, the combination of ECL with CE has been used as a powerful tool for the determination of compounds such as thrombin (16), DNA (17), amino acids (18), various drugs (19)(20)(21)(22)(23)(24)(25)(26)(27)(28) and NADH (29). Most of these analytes contain tertiary amines, which provide good ECL intensities in reaction with [Ru(bpy) 3 ] 3+ without prior derivatization.…”
Section: +mentioning
confidence: 99%
“…-based electrochemiluminescence (ECL) has become an important detection method because it is simple and economical and has low background noise, high sensitivity, good selectivity and wide dynamic linear range (14,15). Recently, the combination of ECL with CE has been used as a powerful tool for the determination of compounds such as thrombin (16), DNA (17), amino acids (18), various drugs (19)(20)(21)(22)(23)(24)(25)(26)(27)(28) and NADH (29). Most of these analytes contain tertiary amines, which provide good ECL intensities in reaction with [Ru(bpy) 3 ] 3+ without prior derivatization.…”
Section: +mentioning
confidence: 99%
“…15,29,30 In this paper, the urine samples were mixed with 50 μL 0.1 mol/L NaOH and 2 mL ethyl acetate, shaken for 5 min and centrifuged for 10 min at 12000 r/min. 31 The upper layer was transfered to a clean tube and dried under a stream of dry nitrogen at 80 C. Subsequently, the dry residue was dissolved in 200 μL of DDW, and the solution was filtered before analysis.…”
Section: Sample Preparationmentioning
confidence: 99%
“…The excretion amounts of PRO were obtained by multiplying the PRO concentration with the volume of urine. 31 The relationship between the excretion rate and the center of time interval was shown in Fig. 7.…”
Section: Pharmacokinetics Of Promentioning
confidence: 99%
“…Chemiluminescence (CL), including electrochemiluminescence (ECL) analysis often offers lower background noise, inherent higher detection sensitivity, and has become a candidate for a new and sensitive CE detection scheme. Especially, CE combining with ECL (CE–ECL) based on tris(2,2′‐bipyridyl) ruthenium (II) ( Ru ( bpy )32+), as an efficient and sensitive analytical technique, has been extensively applied for the determination of analytes containing alkyl amines group . However, as far as we know, there are no reports on the application of CE–ECL assay to quantitative analysis of LH or IF.…”
Section: Introductionmentioning
confidence: 99%