2019
DOI: 10.2174/1573412914666181011124515
|View full text |Cite
|
Sign up to set email alerts
|

Pharmacokinetic Study of Deltaline in Mouse Blood Based on UPLCMS/ MS

Abstract: Introduction: Deltaline, an aconitine-type alkaloid, was detected in mouse blood using an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method, and the pharmacokinetics of deltaline following intravenous administration in mice was studied. </P><P> Materials and Methods: The gelsenicine was used as the internal standard (IS). Deltaline and IS were eluted at a flow rate of 0.4 ml/min and separated on a UPLC BEH C18 column by gradient elution using acetonitrile and 10 m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…By optimizing ion ionization parameters, the selected quantified ions were set at m/z 369.2⟶226.0 for hirsutine, and m/z 367⟶169.9 for hirsuteine. HPLC conditions were as far as possible from separating endogenous interfering substances from analyte and internal standard, and the chromatographic behavior of the column and mobile phase plays a decisive role [20][21][22]. BEH C18 (2.1 mm × 50 mm, 1.7 μm) can obtain satisfactory peak time and peak shape.…”
Section: Resultsmentioning
confidence: 99%
“…By optimizing ion ionization parameters, the selected quantified ions were set at m/z 369.2⟶226.0 for hirsutine, and m/z 367⟶169.9 for hirsuteine. HPLC conditions were as far as possible from separating endogenous interfering substances from analyte and internal standard, and the chromatographic behavior of the column and mobile phase plays a decisive role [20][21][22]. BEH C18 (2.1 mm × 50 mm, 1.7 μm) can obtain satisfactory peak time and peak shape.…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, the acetonitrile proteinprecipitation method was chosen as a pretreatment method for samples. The optimization of the extract of target resulted in an acceptable sensitivity and matrix effect [24][25][26][27][28]. As for the complication of the rat plasma samples, the addition of 200 μL acetonitrile could meet the requirements of removing the proteins and other potential interferences out of 50 μL plasma samples.…”
Section: Resultsmentioning
confidence: 99%
“…It was also an important task to select the best internal standard during the method development [13][14][15][16][17]. In this experiment, several compounds including diazepam, carbamazepine, oxypeucedanin hydrate, bupivacaine, and lidocaine were compared.…”
Section: Discussionmentioning
confidence: 99%