2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)
DOI: 10.1109/nssmic.2000.949120
|View full text |Cite
|
Sign up to set email alerts
|

Phantom and animal imaging studies using PLS synchrotron X-rays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…Although it is assumed that the monochromatic SR beam offers high quality image acquisitions, especially when soft X-rays are used, due to the elimination of beam hardening artifacts related to use of polychromatic X-rays, the higher monochromaticity causes lower flux resulting in longer image acquisition times, of the order of a few seconds, for each projection [7], [16], and [17]. The PLS 5C1 imaging system with an unmonochromatized SR source demonstrated shorter image acquisition times, of the order of a few tens of a millisecond, permitting real-time imaging and high quality images, as compared with conventional imaging system, on a microscopic scale, for a variety of samples, across the fields of materials science, medicine and biology [1] and [2], [9], and [10].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although it is assumed that the monochromatic SR beam offers high quality image acquisitions, especially when soft X-rays are used, due to the elimination of beam hardening artifacts related to use of polychromatic X-rays, the higher monochromaticity causes lower flux resulting in longer image acquisition times, of the order of a few seconds, for each projection [7], [16], and [17]. The PLS 5C1 imaging system with an unmonochromatized SR source demonstrated shorter image acquisition times, of the order of a few tens of a millisecond, permitting real-time imaging and high quality images, as compared with conventional imaging system, on a microscopic scale, for a variety of samples, across the fields of materials science, medicine and biology [1] and [2], [9], and [10].…”
Section: Discussionmentioning
confidence: 99%
“…We used the unmonochromatized SR X-ray beam for acquiring projection data in real time and demonstrated high quality images with micrometer resolution and phase contrast at object boundaries based on the refractive index rather than on the absorption versus monochromatic SR X-ray imaging systems of previous studies [1] and [2], [9] and [10]. This study presents the results of unmonochromatized SR CT images for cancerous human breast tissue as a soft tissue representative, and mouse vertebras as a hard tissue representative.…”
Section: Introductionmentioning
confidence: 99%
“…For example, it has recently been demonstrated that this approach can perform real time, high resolution coherence-based contrast imaging on live animals. 9 , 10 The purpose of this paper to establish the desired characteristics and comparative merits of this specific approach based on coherence-based contrast imaging, in order to evaluate its potential uses as a clinical diagnostic and pathological tool.…”
Section: Introductionmentioning
confidence: 99%