2020
DOI: 10.1049/iet-gtd.2019.1536
|View full text |Cite
|
Sign up to set email alerts
|

PFR ancillary service in low‐inertia power system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 46 publications
0
5
0
Order By: Relevance
“…Finally, due to IBR, North American Electric Reliability Corporation and Hydro-Québec TransÉnergie (HQT) [45] observed a decrease in their respective system inertia and frequency response, which both proposed the use of synthetic inertia as a viable remedy. The Electric Reliability Council of Texas (ERCOT), in the United States of America (USA), has recently faced some technical issues due to the high IBR [46]. Issues arose as overall ERCOT inertia declined from 152 GW.s to 130 GW.s between 2015 and 2017, which was partially attributed to the reduction in the net load [47].…”
Section: Rate Of Change Of Frequency In Large Synchronous Areasmentioning
confidence: 99%
“…Finally, due to IBR, North American Electric Reliability Corporation and Hydro-Québec TransÉnergie (HQT) [45] observed a decrease in their respective system inertia and frequency response, which both proposed the use of synthetic inertia as a viable remedy. The Electric Reliability Council of Texas (ERCOT), in the United States of America (USA), has recently faced some technical issues due to the high IBR [46]. Issues arose as overall ERCOT inertia declined from 152 GW.s to 130 GW.s between 2015 and 2017, which was partially attributed to the reduction in the net load [47].…”
Section: Rate Of Change Of Frequency In Large Synchronous Areasmentioning
confidence: 99%
“…The integration of renewable energy sources such as wind turbines (WTs) in the power system has increased significantly. Unlike the synchronous generators (SGs), WTs are connected to the power system through power electronic converters that lead to a noticeable reduction in the system inertia [1]. These beside uncertainties associated with generation power of WTs lead to frequency excursions which impose severe challenges to operators of power systems in maintaining frequency security [2].…”
Section: Introductionmentioning
confidence: 99%
“…More detailed models of the governor responses are adopted in [25][26] to calculate the pricing of PFR influenced by different dynamic characteristics of the governors. The problem formulation accounting for PFR constraints in unit commitment is described in [27]. Those theoretic studies focused primarily on the provision of PFR from synchronous generators without considering other viable resources.…”
Section: Introductionmentioning
confidence: 99%
“…However, these theoretic works reported in [20][21][22][23][24][25][26][27][28][29] have been performed assuming that no changes are applied to existing AS products. The practical effort to reinvent the AS products is still lacking, but it is imperative to incentivize the resources like batteries to provide fast frequency response capabilities.…”
Section: Introductionmentioning
confidence: 99%