1963
DOI: 10.1002/aic.690090124
|View full text |Cite
|
Sign up to set email alerts
|

Perturbation velocities in gas‐liquid partition chromatographic columns

Abstract: = suffix denoting shape of channel t = time, hr.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
16
0

Year Published

1963
1963
1983
1983

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(18 citation statements)
references
References 1 publication
2
16
0
Order By: Relevance
“…If we neglect the adsorption of helium, the fist moment (mean residence time) for a pulse of hydrocarbon injected into a mixed carrier stream (mole fraction x ) is given by ( Stalkup and Deans, 1963) / d c ) ] . Chromatographic isotherms determined in this way are compared with the gravimetric isotherms in Figure 1.…”
Section: Resultsmentioning
confidence: 99%
“…If we neglect the adsorption of helium, the fist moment (mean residence time) for a pulse of hydrocarbon injected into a mixed carrier stream (mole fraction x ) is given by ( Stalkup and Deans, 1963) / d c ) ] . Chromatographic isotherms determined in this way are compared with the gravimetric isotherms in Figure 1.…”
Section: Resultsmentioning
confidence: 99%
“…Theoretical approaches designed for these specific circumstances have appeared in the literature but are not readily adaptable to more general systems. Generalized theories for systems of multiple interfering species have been outlined by Stalkup,and Deans (1963), Helfferich and Klein (1970), and by Deans et al (1970), but the variety of end-use equations that have been determined for specific experimental situations is very limited.…”
Section: Scopementioning
confidence: 99%
“…Isotopic tracers have been used for some determinations at finite concentration (Stalkup and Deans, 1963;Gilmer and Kobayashi, 1964; Koonce et al, 1965) and can be used for multicomponent systems with any number of species but the method is not always feasible for lack of the needed tracers. The objective of this work was to develop perturbation gas chromatography equations for sorption in multicomponent, finite concentration systems that are not limited to stoichiometric exchange.…”
Section: Scopementioning
confidence: 99%
“…Flow rates from the cylinder are controlled by valve (1) and are measured with a soap-bubble flowmeter. A small portion of carrier gas controlled by valve (4) goes through a reference line.…”
Section: Apparatus and Proceduresmentioning
confidence: 99%