Personnel neutron dosimetry at Department of Energy facilities

Abstract: PNL-3213 UC-41 NOTICE This report was prepared as an account of work sponsored by the United States Government. Neither the United States nor the Department of Energy, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any information, apparatus, product or proce~s disclosed, or represents that its use would not infringe privately ow… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
12
0

Year Published

1981
1981
2011
2011

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 22 publications
1
12
0
Order By: Relevance
“…For multi-element dosimeters such as the 8816 dosimeter, energy dependence is less severe with energy compensating algorithms but field measurements may still be necessary to verify dosimeter accuracy. Technical reports of field measurements (Fix et al 1981(Fix et al , 1982Brackenbush et al 1980Brackenbush et al , 1991Endres et al 1996;Scherpelz, Fix, and Rathbone 2000), along with numerous letter reports to HEDP files, have been prepared.…”
Section: Field Measurements Assessments and Intercomparison Studiesmentioning
confidence: 99%
“…For multi-element dosimeters such as the 8816 dosimeter, energy dependence is less severe with energy compensating algorithms but field measurements may still be necessary to verify dosimeter accuracy. Technical reports of field measurements (Fix et al 1981(Fix et al , 1982Brackenbush et al 1980Brackenbush et al , 1991Endres et al 1996;Scherpelz, Fix, and Rathbone 2000), along with numerous letter reports to HEDP files, have been prepared.…”
Section: Field Measurements Assessments and Intercomparison Studiesmentioning
confidence: 99%
“…In fact, field calibration and verification of the personnel neutron dosimetry system are critically important to ensure accurate dose results for the range of neutron spectra encountered in DOE work environments (Brackenbush et al 1980)., The most recent effort to validate dosimeter performance in Hanford work environments is documented by Endres et al (1996). Response characteristics of the Hanford combination neutron dosimeter, implementedJanuary 1995, to laboratory and workplace radiation ' fields are described.…”
Section: 2mentioning
confidence: 99%
“…However, the TLD is extremely sensitive to slow neutron radiation (Brackenbush et al 1980). The Hanford NTA film dosimeters have essentially no response to neutrons having energies less than about 1 MeV.…”
Section: Neutron Energy Dependencementioning
confidence: 99%
“…The energy response of TLD albedo dosimeters is also complex due to the response of the phosphors themselves and the details of the irradiation geometry (Brackenbush 1980). In general, they are very sensitive to low and intermediate energy neutrons.…”
Section: • Acknowledgmentmentioning
confidence: 99%