2020
DOI: 10.1002/acm2.12897
|View full text |Cite
|
Sign up to set email alerts
|

Personalized setting of plan parameters using feasibility dose volume histogram for auto‐planning in Pinnacle system

Abstract: Purpose The personalized setting of plan parameters in the Auto‐Planning module of the Pinnacle treatment planning system (TPS) using the PlanIQ feasibility tool was evaluated for lung cancer conventional fractionated radiotherapy (CFRT). Materials and method We reviewed the records of ten patients with lung cancer who were treated with volumetric modulated arc therapy (VMAT). Three plans were designed for each patient: the clinically accepted manual plan (MP) and two a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
28
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(29 citation statements)
references
References 27 publications
1
28
0
Order By: Relevance
“…For example, the modification of the restriction conditions in the template and the parameter setting of hot and cold spots will affect the result of the APs. (23,24) In addition, the limited number of patients in this study is slightly lower. The result can be more convincing with a larger sample size and more different type of diseases as the research object.…”
Section: Disscusionmentioning
confidence: 88%
“…For example, the modification of the restriction conditions in the template and the parameter setting of hot and cold spots will affect the result of the APs. (23,24) In addition, the limited number of patients in this study is slightly lower. The result can be more convincing with a larger sample size and more different type of diseases as the research object.…”
Section: Disscusionmentioning
confidence: 88%
“…Secondly, although the optimization process of AP reduces the interference of human subjective factors, there are certain subjective factors in the initial settings of AP. For example, the modification of the restriction conditions in the template and the parameter setting of hot and cold spots will affect the result of the APs (23,24). In addition, the number of patients enrolled in this study is limited.…”
Section: Discussionmentioning
confidence: 99%
“…“Impossible DVH (red)” is defined as the DVH generated using the minimum dose that an off‐target voxel must receive given 100% target coverage. Studies that used the PlanIQ TM software have reported improvements in the treatment plan quality 8–13 . Recently, PlanIQ TM was integrated into Autoplan®, which is implemented in Pinnacle and has been clinically applied 9,10 .…”
Section: Introductionmentioning
confidence: 99%