2012
DOI: 10.1371/journal.pone.0046780
|View full text |Cite
|
Sign up to set email alerts
|

Personalized Pseudophakic Model for Refractive Assessment

Abstract: PurposeTo test a pseudophakic eye model that allows for intraocular lens power (IOL) calculation, both in normal eyes and in extreme conditions, such as post-LASIK.MethodsParticipants: The model’s efficacy was tested in 54 participants (104 eyes) who underwent LASIK and were assessed before and after surgery, thus allowing to test the same method in the same eye after only changing corneal topography.ModellingThe Liou-Brennan eye model was used as a starting point, and biometric values were replaced by individ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0
2

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 35 publications
0
12
0
2
Order By: Relevance
“…Surgical procedures were conducted by the same experienced surgeon (FR) under local anesthesia through a microincision of 2.2 mm. Prior to surgery, patients underwent a comprehensive ophthalmological examination including optical biometry and anterior surface optical tomography for the calculation of the power of the IOL using a semicustomized ray-tracing method [ 21 ]. Surgical procedures with IOL implantation were conducted with a difference of 7 days between eyes.…”
Section: Methodsmentioning
confidence: 99%
“…Surgical procedures were conducted by the same experienced surgeon (FR) under local anesthesia through a microincision of 2.2 mm. Prior to surgery, patients underwent a comprehensive ophthalmological examination including optical biometry and anterior surface optical tomography for the calculation of the power of the IOL using a semicustomized ray-tracing method [ 21 ]. Surgical procedures with IOL implantation were conducted with a difference of 7 days between eyes.…”
Section: Methodsmentioning
confidence: 99%
“…Characterization of corneal topography is critical for the assessment of vision quality and for several clinical applications including the diagnosis and management of corneal diseases [1] [3] , the planning of refractive surgery [4] [5] , and the construction of corneal numerical models [6] .…”
Section: Introductionmentioning
confidence: 99%
“…To consider all the potential applications of raytracing for IOL power calculation, the development of new pseudophakic eye models is warranted. 54 …”
Section: Preoperative Evaluation For Toric Intraocular Lens Implantatmentioning
confidence: 99%