2015
DOI: 10.1007/s00216-015-8887-8
|View full text |Cite
|
Sign up to set email alerts
|

Personalized monitoring of therapeutic salicylic acid in dried blood spots using a three-layer setup and desorption electrospray ionization mass spectrometry

Abstract: Desorption electrospray ionization (DESI) mass spectrometry is an emerging technology for direct therapeutic drug monitoring in dried blood spots (DBS). Current DBS methods require manual application of small molecules as internal standards for absolute drug quantification. With industrial standardization in mind, we superseded the manual addition of standard and built a three-layer setup for robust quantification of salicylic acid directly from DBS. We combined a dioctyl sodium sulfosuccinate weave facilitati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(27 citation statements)
references
References 26 publications
0
27
0
Order By: Relevance
“…In contrast, methods for DESI analysis of DBS necessitate relatively high solvent spray volumes (up to 15 μL/min). Using DBS also necessitates relatively high volumes of blood (6–15 μL), thus preventing the deposition of a large number of blood spots in a limited surface. The concept of DESI static profiling of blood droplets also opens a large field for high‐throughput analytics.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In contrast, methods for DESI analysis of DBS necessitate relatively high solvent spray volumes (up to 15 μL/min). Using DBS also necessitates relatively high volumes of blood (6–15 μL), thus preventing the deposition of a large number of blood spots in a limited surface. The concept of DESI static profiling of blood droplets also opens a large field for high‐throughput analytics.…”
Section: Discussionmentioning
confidence: 99%
“…However, it was not possible to obtain a satisfactory sensitivity using dried plasma spots without LLE . Whole blood was also analyzed by DESI using dried blood spots (DBS) and could be used for drug quantification purposes …”
Section: Introductionmentioning
confidence: 99%
“…While semi-quantitation can be simply performed by ambient ionization, the use of internal standards (IS) can significantly improve the limit of quantitation (LOQ), linear dynamic range, and RSD for the analysis. Using salicylic acid isotopologue as the IS, DESI-MS was utilized for the quantitation of therapeutic salicylic acid in rat DBS using a three-layer setup for sampling [44]. Good correlation was observed between quantitative results by DESI-MS and LC-MS/MS (Fig.…”
Section: Ambient Ionizationmentioning
confidence: 99%
“…Quantitative analysis by ambient ionization-MS. (a) Good correlation between DESI-MS and LC-MS/MS quantitative results of SA in rat DBS using the three-layer setup (Reprinted with permission from [44], Elsevier) (b) Calibration curve of sitamaquine in rat blood (10–10, 000 ng/ml) using 570 ng/ml sitamaquine- d 10 as the IS. (Reprinted with permission from [45], Wiley) (c) Calibration curve for the analysis of sitamaquine in rat blood by liquid extraction-based surface sampling and ionization using sitamaquine- d 10 as the IS.…”
Section: Figmentioning
confidence: 99%
“…These achievements suggest a promising direction in technical development for direct MS analysis of complex samples. Although several works have been done by DESI[17] and paper spray[18,19], direct MS analysis of biofluid is still inefficient and remains challenging.…”
Section: Introductionmentioning