IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society 2016
DOI: 10.1109/iecon.2016.7793711
|View full text |Cite
|
Sign up to set email alerts
|

Personal thermal comfort management in existing office buildings using energy-efficient fans

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 8 publications
0
4
0
Order By: Relevance
“…Accordingly, controlling “air temperature” and “air velocity” achieves an acceptable thermal comfort in kitchen (cooking) areas (Zainuddin et al, 2014). In hot and humid environments, typically the SET index was employed to determine the occupant thermal comfort when performing CFD simulations (Han et al, 2007; Hussin et al, 2014; Malek et al, 2015; Damian, 2017; Nazarian et al, 2017; Shetty et al, 2016).…”
Section: Introductionmentioning
confidence: 99%
“…Accordingly, controlling “air temperature” and “air velocity” achieves an acceptable thermal comfort in kitchen (cooking) areas (Zainuddin et al, 2014). In hot and humid environments, typically the SET index was employed to determine the occupant thermal comfort when performing CFD simulations (Han et al, 2007; Hussin et al, 2014; Malek et al, 2015; Damian, 2017; Nazarian et al, 2017; Shetty et al, 2016).…”
Section: Introductionmentioning
confidence: 99%
“…In China also at the hot and humid climate for occupant's thermal comfort inside the residence same SET index was used [29]. Accordingly, in Singapore Shetty et al [30] have researched hot and moist environments using energy-efficient fans. Used the SET index based on the "ASHRAE 55" standard to assess the thermal comfort of occupants in the building for energysaving and compared it to field measurement data [30].…”
Section: Introductionmentioning
confidence: 99%
“…Hence, designing a sustainable building does not mean that high cost of the technology implementation is in the picture but it is more about selecting the right technologies that can cater well for the building's condition (Nazi et al, 2015). Shetty et al (2016) examined to pick up bits of knowledge on the utilization of individual fans regarding temperature, time and different components and information are contrasted and the SET (Standard Effective Temperature). The proposed work recommends rules on fusing tenant inclinations in a decentralized structure for better warm solace and enhanced vitality funds in existing cooled structures.…”
Section: Introductionmentioning
confidence: 99%
“…The proposed work recommends rules on fusing tenant inclinations in a decentralized structure for better warm solace and enhanced vitality funds in existing cooled structures. Beginning outcomes uncover that identifying the low-action and high-movement breaks is significant to comprehend the tenant inclinations for the entire working day (Shetty et al, 2016). Kontes et al (2017) have defined an experimental simulation protocol involving two office buildings; the buildings have contrasting geometrical and construction characteristics as well as different building services systems for meeting heating and cooling demands, occupant thermal comfort is estimated using the Fanger index as defined in ISO 7730.…”
Section: Introductionmentioning
confidence: 99%