1979
DOI: 10.1080/15298667991430028
|View full text |Cite
|
Sign up to set email alerts
|

Personal sampler for NOx

Abstract: A personal sampler system for NOx (NO + NO2) and NO2 has been developed for monitoring workplace air. The NO2 sampler previously reported from this laboratory uses triethanolamine to trap NO2 which diffuses through a tube of appropriate dimensions. The NOx sampler contains the same elements as the NO2 device, but it is also fitted with a chromic acid impregnated disc; this disc converts NO to NO2 which is then trapped by the triethanolamine along with preformed NO2. The trapped NO2 in all cases is determined a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
26
0
1

Year Published

1991
1991
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(27 citation statements)
references
References 0 publications
0
26
0
1
Order By: Relevance
“…Se utilizaron tubos tipo Palmes de acrílico ( [3,4]), construidos en nuestro laboratorio con tubos de acrílico de 7 cm de longitud y 12 mm de diámetro interno. En un extremo, sostenidos con una tapa de polietileno, se ubicaron dos discos de malla de acero inoxidable (0,2 x 0,2 mm) humedecidas con una mezcla trietanolamina (90% p/v), mientras que el otro extremo se selló con otra tapa similar.…”
unclassified
“…Se utilizaron tubos tipo Palmes de acrílico ( [3,4]), construidos en nuestro laboratorio con tubos de acrílico de 7 cm de longitud y 12 mm de diámetro interno. En un extremo, sostenidos con una tapa de polietileno, se ubicaron dos discos de malla de acero inoxidable (0,2 x 0,2 mm) humedecidas con una mezcla trietanolamina (90% p/v), mientras que el otro extremo se selló con otra tapa similar.…”
unclassified
“…These samplers measured the workers' exposures to respirable silica, NO, NO 2 , and noise. The sampling and analytical methodologies (2,3,4,5,6) are presented in Table 1.…”
Section: A Environmentalmentioning
confidence: 99%
“…Copies of this report have been sent to: (Cyclone/Impactor) NIOSH Method 7500 (5) Oxides of Nitrogen Passive Chromic acid disc (N0 x , NO, NO 2 ) Sampler Triethanolamine Visible Absorption (Passive Dosimeter) Spectrophotometry (3,4) Nitrogen Dioxide 100 cc/stroke Short-Term Detector Tube Direct Reading (6) Carbon Monoxide 0.02 Long-Term Detector Tube Direct Reading (6) Carbon Monoxide 100 cc/stroke Short-Term Detector Tube Direct Reading (6) Respirable Free 1.7 PVC Filter/Cyclone NIOSH methods 7500/0500, Silica X-Ray Diffraction (5) Notes: LPM-Liters Per Minute NO x Oxides of Nitrogen including, Nitric Oxide (NO), and Nitrogen Dioxide (NO 2 ). (8) MSHA STANDARD (2) Coal Tar A -All samples were collected on operated equipment or in areas where equipment was operating.…”
Section: B Medicalmentioning
confidence: 99%
“…Nitric oxide and nitrogen dioxide were collected using the Palmes (3,4) passive dosimeter. The passive dosimeters are rigid, cylindrical, plastic tubes with a mesh screen at one end of the tube that is coated with triethanolamine.…”
Section: A Environmentalmentioning
confidence: 99%