2012
DOI: 10.1016/j.chroma.2012.06.051
|View full text |Cite
|
Sign up to set email alerts
|

Person-portable gas chromatography: Rapid temperature program operation through resistive heating of columns with inherently low thermal mass properties

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(11 citation statements)
references
References 48 publications
0
11
0
Order By: Relevance
“…In order to overcome the drawback of time-consuming separations using typical capillary column methods, isothermal GC temperature programs have been adopted [47]. Just prior to 2000, resistive column heating (low thermal-mass (LTM)) technology, an innovation in the field of GC that enabled fast temperature ramping, has been developed [48,49]. As a result, GC-MS became more feasible for on-site confirmation of a wide range of CWAs.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to overcome the drawback of time-consuming separations using typical capillary column methods, isothermal GC temperature programs have been adopted [47]. Just prior to 2000, resistive column heating (low thermal-mass (LTM)) technology, an innovation in the field of GC that enabled fast temperature ramping, has been developed [48,49]. As a result, GC-MS became more feasible for on-site confirmation of a wide range of CWAs.…”
Section: Introductionmentioning
confidence: 99%
“…Hapsite has been used as field analysis instrument for mainly quantifying volatile organic chemicals [57]. The latest version of the Hapsite ER [58] provides extended target analysis by adopting SPME and a thermal desorbing device at the inlet [49]. This inlet system is reported to be superior to the original sampling probe, which was found to have a hard memory effect due to condensation of less volatile compounds in the probe [59].…”
Section: Introductionmentioning
confidence: 99%
“…Within field‐deployable technologies, gas chromatography (GC)–MS instruments are the most promising candidates . In addition, resistive column heating (low thermal mass (LTM)) technology provides rapid on‐site confirmation of a wide range of CWAs . For example, a GC–MS machine consisting of an LTM capillary column GC and an electron ionization (EI) toroidal ion trap MS can identify CWAs by combining with solid‐phase microextraction (SPME) .…”
Section: Introductionmentioning
confidence: 99%
“…At present, gas chromatograph has been widely used in medicine, food safety, petrochemical [1], environmental science [2], and many other fields. However, with gas chromatograph applied to process analysis [3], quality testing [4], environment online monitoring [5], and sudden emergency monitoring, the contradiction between non-real-time measurement and the demand of the real-time measurement in various fields is becoming more and more obvious. Therefore, the application of gas chromatograph into the field of measure is restricted.…”
Section: Introductionmentioning
confidence: 99%