2000
DOI: 10.1016/s0584-8547(00)00194-4
|View full text |Cite
|
Sign up to set email alerts
|

Permanent modification in electrothermal atomic absorption spectrometry — advances, anticipations and reality

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
40
0
3

Year Published

2003
2003
2015
2015

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 104 publications
(45 citation statements)
references
References 65 publications
2
40
0
3
Order By: Relevance
“…In order to reduce the major interferences caused in real samples, we performed further investigations to find an effective chemical modifier. Tsalev et al 12 proposed a systematic review and detailed discussion on the characteristic features of chemical modifiers used in ETAAS. Volynsky 13 gave a critical review on the investigation of the mechanism of chemical modifiers.…”
Section: 7-9mentioning
confidence: 99%
“…In order to reduce the major interferences caused in real samples, we performed further investigations to find an effective chemical modifier. Tsalev et al 12 proposed a systematic review and detailed discussion on the characteristic features of chemical modifiers used in ETAAS. Volynsky 13 gave a critical review on the investigation of the mechanism of chemical modifiers.…”
Section: 7-9mentioning
confidence: 99%
“…The curve was obtained from 10 calibration plots, ranging from 0.01 to 3.33 µg L −1 . As shown in Table 2 It is well known that the high temperature applied for the Cd pyrolysis decreases the lifetime of graphite tubes as well as the corrosive action of some modifiers [42]. The lifetime of the graphite tube using the chemical modifier and the high temperature conditions was around 650 firings.…”
Section: Analytical Figures Of Meritmentioning
confidence: 95%
“…8 The use of a permanent modifier simplifies the procedure compared to the addition of a modifier in solution to each sample aliquot. 1,19 According to a study, 9 the permanent chemical modifiers can be used for direct SS-ETAAS, despite the sample not being in intimate contact with the modifier. A straightforward procedure was proposed for the determination of mercury in biological materials using solid sampling and high-resolution continuum source electrothermal atomic absorption spectrometry (HR-CS-ETAAS) in a graphite tube with calibration against aqueous standards stabilized by potassium permanganate, with the elimination of the pyrolysis stage and without the use of any chemical modifiers of the platform surface.…”
Section: Introductionmentioning
confidence: 99%