1997
DOI: 10.1034/j.1600-0501.1997.080404.x
|View full text |Cite
|
Sign up to set email alerts
|

Periodontal parameters of osseointegrated dental implaits. A 4‐year controlled follow‐up study

Abstract: The aim of this study was to evaluate the periodontal parameters of osseointegrated dental implants. The condition of the peri-implant mucosa was assessed using periodontal parameters, i.e., of plaque index, bleeding on probing, probing pocket depth, probing attachment level and Periotest scores as well as a radiographic parameter, over a 4-year follow-up period. 32 non-submerged ITI dental implants, all placed in the mandible, were studied in 12 patients who had good oral hygiene. All patients were regularly … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

14
27
0
1

Year Published

2004
2004
2019
2019

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 50 publications
(42 citation statements)
references
References 0 publications
14
27
0
1
Order By: Relevance
“…However, some studies have reported lower rates of periimplant bleeding on probing. 40,41 A possible explanation for these differences pointed toward the probe force used in the probing procedures around implants. According to Ferreira et al, 3 it has not been clearly defined whether periimplant BOP could represent a reliable parameter for the identification of the presence of periimplant disease.…”
Section: Discussionmentioning
confidence: 98%
“…However, some studies have reported lower rates of periimplant bleeding on probing. 40,41 A possible explanation for these differences pointed toward the probe force used in the probing procedures around implants. According to Ferreira et al, 3 it has not been clearly defined whether periimplant BOP could represent a reliable parameter for the identification of the presence of periimplant disease.…”
Section: Discussionmentioning
confidence: 98%
“…Klinik ölçümlerde standart kuvvet uygulandığı için SK'nin travmatik neden ile oluşmadığı düşünülmektedir. Nishimura ve ark., 25 uygulanan kuvvetin fazla olması nedeniyle hatalı olarak sondalamada kanama tespit edilebildiğini, Lekholm ve ark. 26 ise bu klinik bulgunun histolojik, mikrobiyolojik ve radyolojik bulgularla korelasyon göstermediği, sağlıklı durumda da kanamanın pozitif olabileceğini bildirilmişlerdir.…”
Section: Discussionunclassified
“…[15] 6. Dental Implants:Nishimura K. (1997) [16] and Kayikvioglu A. (2003) [17] observed that an increased pressure or loading on the muscles of mastication, did interfere with the osseointegration around the dental implants.…”
Section: Dermal Fillers -These Are the Filler Productsmentioning
confidence: 99%