Periodic sterility assessment of materials stored for up to 6 months at continuous microbial contamination risk: Laboratory study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 3 publications
0
3
0
1
Order By: Relevance
“…About 79% of the healthcare workers in primary and secondary care hospitals in Nepal thought that wrapped sterilized medical devices could be stored for seven days at room temperature before use. A shelf-life of 7 days is very much less than the shelf-life indicated by many previous studies, and there is be growing support for the event-based determination of shelf-life rather than the time-based shelf-life of sterilized medical devices [ 46 49 ]. When event-based shelf-life is implemented, wrapped medical devices are stored for a longer time, i.e.…”
Section: Discussionmentioning
confidence: 99%
“…About 79% of the healthcare workers in primary and secondary care hospitals in Nepal thought that wrapped sterilized medical devices could be stored for seven days at room temperature before use. A shelf-life of 7 days is very much less than the shelf-life indicated by many previous studies, and there is be growing support for the event-based determination of shelf-life rather than the time-based shelf-life of sterilized medical devices [ 46 49 ]. When event-based shelf-life is implemented, wrapped medical devices are stored for a longer time, i.e.…”
Section: Discussionmentioning
confidence: 99%
“…One study verified that, after two years, 100% (152) of the sterilized and stored packages, which suffered no adverse events, were sterile ( 22 ) . Another study concluded that even after exposure to the microorganism Serratia marcescens , an item with a safe microbial barrier remained sterile after 180 days ( 23 ) . Event-related sterility is safe and should, therefore, replace time-related expiration ( 22 ) .…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, potentially infectious aerosolized particles may land on sterile packages that are not contained or covered in the OR. There also is evidence that instruments wrapped or packaged and sterilized according to the manufacturer’s instructions for use remain sterile until something occurs that affects sterility (eg, tear, puncture, exposure to out‐of‐range humidity), which is known as event‐related sterility 1,8‐12 …”
Section: Containment Of Unopened Sterile Supplies During Proceduresmentioning
confidence: 99%