2019
DOI: 10.1016/j.ab.2019.113443
|View full text |Cite
|
Sign up to set email alerts
|

Perfused murine heart optical transmission spectroscopy using optical catheter and integrating sphere: Effects of ischemia/reperfusion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 36 publications
0
4
0
Order By: Relevance
“…Transmural absorbance spectroscopy is a robust method for monitoring cardiac chromophores in the intact heart (Bauer et al., 2019; Femnou et al., 2017; Giles et al., 2018; Kuzmiak‐Glancy et al., 2018). In addition to mitochondrial chromophores and OxyMb and DeoxyMb, these studies evaluated the ability of optical spectroscopy to monitor MetMb, enabling a kinetic evaluation of the Mb/MbR system in the intact heart.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Transmural absorbance spectroscopy is a robust method for monitoring cardiac chromophores in the intact heart (Bauer et al., 2019; Femnou et al., 2017; Giles et al., 2018; Kuzmiak‐Glancy et al., 2018). In addition to mitochondrial chromophores and OxyMb and DeoxyMb, these studies evaluated the ability of optical spectroscopy to monitor MetMb, enabling a kinetic evaluation of the Mb/MbR system in the intact heart.…”
Section: Resultsmentioning
confidence: 99%
“…Spectral fitting was performed using chromophore reference standards and a previously described LabVIEW-based program. Cytochromes c and c 1 , as well as Complex III haem b H and b L reference spectra were identical to previous publications (Bauer et al, 2019;Femnou et al, 2017;Giles et al, 2018;Kuzmiak-Glancy et al, 2018). Rabbit oxymyoglobin (OxyMb), deoxymyoglobin (DeoxyMb) and metmyoglobin (MetMb) reference spectra were collected from commercially available rabbit heart myoglobin (Life Diagnostics, West Chester, PA, USA).…”
Section: Spectral Analysesmentioning
confidence: 96%
“…Furthermore, the mitoSOX signal increase in early reperfusion was inhibited by S1QEL, a specific inhibitor of ROS generation at Cx-I 59 , so we consider any contribution from other poorly-characterized oxidation sources to be minimal. Secondly, the mitoSOX signal is impacted both by its distribution between extracellular, cytosolic and mitochondrial compartments 37 , and by the primary and secondary filter effects from endogenous chromophores 47, 55 (see methods section 2.4). However, our use of fully-oxidized mitoSOX as a control (Supplementary Figure 1) ensures that any changes in the mitoSOX signal we observed originated only from in-situ probe oxidation, and not from redistribution of the probe or changes in the absorbance of myoglobin, cytochromes, etc.…”
Section: Discussionmentioning
confidence: 99%
“…Although similar spectrofluorometric cardiac perfusion apparatus has previously been constructed 32,[44][45][46][47][48] , prior efforts have used larger animal hearts (rats, guinea pigs) or have not simultaneously measured cardiac function. To the best of our knowledge, this is the first study of mouse hearts with simultaneous fluorescence and functional assessment.…”
Section: Cardiac Fluorescencementioning
confidence: 99%
“…Heart rate was calculated from the sinusoidal flow rate curve 36 The arrangement of the optics was previously detailed. 36,37 In brief, a Langendorff-perfused mouse heart was placed in a transparent glass chamber enclosed in a water jacket. The chamber had a white base to prevent direct illumination of the sensor.…”
Section: Langendorff Perfusion Of Mouse Heartsmentioning
confidence: 99%