2008
DOI: 10.1016/j.measurement.2007.06.003
|View full text |Cite
|
Sign up to set email alerts
|

Performances of interferometric optical transmission diagnostic for in situ and real-time control of magnetron sputtering deposition process

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 12 publications
0
7
0
Order By: Relevance
“…Films of different thicknesses were deposited by varying the deposition time. The thicknesses of the coatings were determined by analysing the transmittance-wavelength curves measured with a Varian Cary 5000 optical spectrometer thanks to a programme developed by PVDco Ltd. [21,22] using a similar layer deposited on a glass substrate. Before depositing the Pd layers by PVD on one side of the electrolyte, gold counter and reference electrodes were deposited on the opposite side of the pellet from a gold paste (Metalor A1644) annealed at 800°C under air for 2 h. The catalytic activity measurements for the DOM were carried out at atmospheric pressure in a specific quartz reactor described elsewhere [23].…”
Section: Methodsmentioning
confidence: 99%
“…Films of different thicknesses were deposited by varying the deposition time. The thicknesses of the coatings were determined by analysing the transmittance-wavelength curves measured with a Varian Cary 5000 optical spectrometer thanks to a programme developed by PVDco Ltd. [21,22] using a similar layer deposited on a glass substrate. Before depositing the Pd layers by PVD on one side of the electrolyte, gold counter and reference electrodes were deposited on the opposite side of the pellet from a gold paste (Metalor A1644) annealed at 800°C under air for 2 h. The catalytic activity measurements for the DOM were carried out at atmospheric pressure in a specific quartz reactor described elsewhere [23].…”
Section: Methodsmentioning
confidence: 99%
“…Coating thickness was also determined ex-situ by optical transmittance measurements performed with a UV-visible-NIR Spectrophotometer (UV3600, produced by Shimadzu) using a principle described in [7]. The transmittance curves were fitted by Scout software developed by W. Theiss.…”
Section: Structural and Morphological Characterisationmentioning
confidence: 99%
“…Total pressure was measured using an absolute MKS Baratron pressure gauge. Coating thickness was measured by analysing the transmittance-wavelength curves measured with a Varian Cary 5000 optical spectrometer based on a programme developed by PVDco Ltd [28,29]. The electrochemical catalyst consisted of a dense and continuous thin Pt film (geometric area of 1.5 cm 2 , Pt loading of 65 lg cm -2 ) deposited on one side of the YSZ disc (17 mm in diameter and 0.5 mm thick).…”
Section: Electrochemical Catalyst Preparationmentioning
confidence: 99%