Performance tests and comparison of microdosimetric measurements with four tissue-equivalent proportional counters in scanning proton therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
12
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(15 citation statements)
references
References 29 publications
3
12
0
Order By: Relevance
“…TEPCs have been applied to measure single‐event distributions of many types of ionizing radiation, including photons, neutrons, and heavy charged particles. These detectors can and have been used to conduct measurements around proton and carbon therapy beams . The event‐size spectra obtained during measurements can range from around 0.1 keV/μm to > 1000 keV/μm.…”
Section: Measurement Approachesmentioning
confidence: 99%
See 1 more Smart Citation
“…TEPCs have been applied to measure single‐event distributions of many types of ionizing radiation, including photons, neutrons, and heavy charged particles. These detectors can and have been used to conduct measurements around proton and carbon therapy beams . The event‐size spectra obtained during measurements can range from around 0.1 keV/μm to > 1000 keV/μm.…”
Section: Measurement Approachesmentioning
confidence: 99%
“…These detectors can and have been used to conduct measurements around proton and carbon therapy beams. 163,241,242 The event-size spectra obtained during measurements can range from around 0.1 keV/lm to > 1000 keV/lm. The absorbed dose contributions from various types of secondary particles can be differentiated via the microdosimetric spectrum because different secondary particles have different lineal energies in the active volume.…”
Section: B2 Fast Neutron Detectorsmentioning
confidence: 99%
“…Events encountering significant electronic noise below the so-called low energy threshold (0.3 keV·μm −1 for the HAWK used here) are not recorded. For data analysis, a simple coefficient (the average of correction factor determined for 60 Co and 137 Cs gamma-rays) was applied ( 46 ). No compensation of the counting loss due to dead time is included in the analysis software.…”
mentioning
confidence: 99%
“…A dedicated experiment was organised for microdosimetric spectra measurements around a paediatric phantom (Farah et al 2017). Four different tissue-equivalent proportional counters (TEPC), first compared in standard neutron and gamma radiation fields, were used.…”
Section: One Of the Important Conclusion From This Work Comes From A ...mentioning
confidence: 99%