Proceedings of the 1982 IEEE Second Working Conference on Current Measurement
DOI: 10.1109/ccm.1982.1158439
|View full text |Cite
|
Sign up to set email alerts
|

Performance test results for the EG&G vector measuring current meter (VMCM)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 2 publications
0
8
0
Order By: Relevance
“…By that time a commerical source of self-contained 316 stainless steel bearings had been found, and these bearings were fitted to the hub assemblies of the EG&G VMCMs deployed in CODE 2 with only minor modification to the hub cap design. Tow tank tests conducted by Mero [1982] show that the steady flow calibration curves for the EG&G VMCM sensor sets (incorporating the CODE 1 design) were identical within experimental error to those reported by Weller and Davis [1980]. Since the new hub design does not change the external shape of the hub, we expect that the flow response of the SIO and EG&G propeller sensors in CODE I and CODE 2 should be identical.…”
Section: Vmcmmentioning
confidence: 59%
See 3 more Smart Citations
“…By that time a commerical source of self-contained 316 stainless steel bearings had been found, and these bearings were fitted to the hub assemblies of the EG&G VMCMs deployed in CODE 2 with only minor modification to the hub cap design. Tow tank tests conducted by Mero [1982] show that the steady flow calibration curves for the EG&G VMCM sensor sets (incorporating the CODE 1 design) were identical within experimental error to those reported by Weller and Davis [1980]. Since the new hub design does not change the external shape of the hub, we expect that the flow response of the SIO and EG&G propeller sensors in CODE I and CODE 2 should be identical.…”
Section: Vmcmmentioning
confidence: 59%
“…Steady tow tank experiments conducted by R. A. Weller (personal communication, 1985) and Mero [1982] confirm that the SIO and EG&G VMCMs have essentially identical steady flow characteristics and horizontal and vertical cosine responses. The primary deviations of both instruments from a perfect cosine response are due to flow distortion caused by the instrument support rods and electronics housing.…”
Section: In a Second Class Of Unsteady Laboratory Experiments Conductmentioning
confidence: 76%
See 2 more Smart Citations
“…The VACM is specifically designed to measure currents even when oscillatory currents from large surface waves are present. A detailed description of the design and measurement characteristics is provided by McCullough, 1975, Mero, 1982and Beardsleyetal., 1987. The meter measured the average current direction and speed every 15 minutes.…”
Section: Instrumentationmentioning
confidence: 99%