2016
DOI: 10.1117/12.2232133
|View full text |Cite
|
Sign up to set email alerts
|

Performance study of the gamma-ray bursts polarimeter POLAR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 8 publications
0
3
0
Order By: Relevance
“…Later on, all the compositions of the detector were developed in succession. One of the typical units is the DMU, thus its performance was also studied [12]. Finally, the integration of FM model was done and the calibration with 100% polarized hard X-rays at the European Synchrotron Radiation Facility (ESRF) was performed with lower beam energies of 110 keV, 80 keV and 60 keV for both on-axis and off-axis tests, and the measured modulation factors agreed well with the Monte-Carlo simulation results.…”
Section: Ground Calibration and Performance Studymentioning
confidence: 68%
See 1 more Smart Citation
“…Later on, all the compositions of the detector were developed in succession. One of the typical units is the DMU, thus its performance was also studied [12]. Finally, the integration of FM model was done and the calibration with 100% polarized hard X-rays at the European Synchrotron Radiation Facility (ESRF) was performed with lower beam energies of 110 keV, 80 keV and 60 keV for both on-axis and off-axis tests, and the measured modulation factors agreed well with the Monte-Carlo simulation results.…”
Section: Ground Calibration and Performance Studymentioning
confidence: 68%
“…However, all these basic performances of the DMU will finally affect the polarization performance of POLAR, so they are also important to be analyzed. In [12] the basic analysis of DMU concluded that the average intrinsic noise of each DMU is typically below 20 ADC channel which means ∼1 keV; the non-uniformity of the gain for all the DMUs is below 3, typically ∼2 and lowest 1.6; the average low threshold of each DMU is ∼15 keV. The tests were done at module level with a laboratory 22 Na radioactive source with the activity of ∼ 55 kBq.…”
Section: Performance At Module Levelmentioning
confidence: 99%
“…One exception is IKAROS/GAP (Yonetoku et al 2011a), a dedicated GRB polarimeter aboard the JAXA solar sail IKAROS which is responsible for the most significant GRB polarization measurements to date (Yonetoku et al 2012). The POLAR instrument aboard the Chinese space station Tiangong 2 is another dedicated GRB polarimeter which was only recently deployed (Sun et al 2016;Orsi et al 2014;Produit et al 2005). POLAR has successfully detected several GRBs in its few months of service (Kole & Marcinkowski 2016;, although no polarization analyses have yet been published.…”
Section: Introductionmentioning
confidence: 99%