2010
DOI: 10.1016/j.jpba.2009.09.029
|View full text |Cite
|
Sign up to set email alerts
|

Performance qualification of an electronic tongue based on ICH guideline Q2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
60
0
1

Year Published

2010
2010
2016
2016

Publication Types

Select...
6
2
2

Relationship

1
9

Authors

Journals

citations
Cited by 92 publications
(61 citation statements)
references
References 18 publications
0
60
0
1
Order By: Relevance
“…1a) The TS-5000Z e-tongue system (abbreviation: I) was equipped with the commercially available sensors SB2AC0, SB2AN0 and SB2BT0 (dedicated to bitter cationic substances), SB2AAE (dedicated to umami), SB2CT0 (dedicated to saltiness) and SB2CA0 (dedicated to sourness), SB2C00 (dedicated to bitter anionic substances) and SB2AE1 (dedicated to astringent substances) and Ag/AgCl-reference electrode. The measurement followed the standard procedure as described by Woertz et al [22,25], using the recommended measurement setup ABCABC (A, B, and C are representatives of sample beakers). Prior to each measurement, a sensor check was performed and only proper working sensors were applied further.…”
Section: 3mentioning
confidence: 99%
“…1a) The TS-5000Z e-tongue system (abbreviation: I) was equipped with the commercially available sensors SB2AC0, SB2AN0 and SB2BT0 (dedicated to bitter cationic substances), SB2AAE (dedicated to umami), SB2CT0 (dedicated to saltiness) and SB2CA0 (dedicated to sourness), SB2C00 (dedicated to bitter anionic substances) and SB2AE1 (dedicated to astringent substances) and Ag/AgCl-reference electrode. The measurement followed the standard procedure as described by Woertz et al [22,25], using the recommended measurement setup ABCABC (A, B, and C are representatives of sample beakers). Prior to each measurement, a sensor check was performed and only proper working sensors were applied further.…”
Section: 3mentioning
confidence: 99%
“…The performance of the test sensing system has been validated based on ICH (International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use) guideline Q2. 17 Because the intensity of the basic tastes is expressed as relative values, we used a single brand of commercial bovine milk (Megamilk; Nippon Milk Community Co. Ltd., Tokyo, Japan) as the standard. Thus, negative values for basic taste mean that the intensity of the basic taste was weaker for human than for bovine milk.…”
Section: Evaluation Of Milk Taste By a Taste Sensormentioning
confidence: 99%
“…The "electronic tongue" can be incorporated here in formulation development. The electronic tongue is a device which detects an electronic signal in a given formulation; the goal is to achieve an electronic signal of the formulation containing the active drug which is similar to formulation containing a placebo (25)(26)(27). A recent paper describes the use of the electronic tongue in formulating a palatable sodium phenylbutyrate preparation, an extremely difficult task (28).…”
Section: Palatability and Taste Maskingmentioning
confidence: 99%