1997
DOI: 10.1063/1.1148082
|View full text |Cite
|
Sign up to set email alerts
|

Performance of the vacuum ultraviolet high-resolution and high-flux beamline for chemical dynamics studies at the Advanced Light Source

Abstract: At the Advanced Light Source an undulator beamline, with an energy range from 6 to 30 eV, has been constructed for chemical dynamics experiments. The higher harmonics of the undulator are suppressed by a novel, windowless gas filter. In one branchline high-flux, 2% bandwidth radiation is directed toward an end station for photodissociation and crossed molecular-beam experiments. A photon flux of 10 16 photon/s has been measured at this end station. In a second branchline a 6.65 m off-plane Eagle monochromator … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
116
0

Year Published

2001
2001
2022
2022

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 188 publications
(119 citation statements)
references
References 17 publications
(14 reference statements)
3
116
0
Order By: Relevance
“…At wavelengths shorter than 80 nm irradiation, approximately 3-5% of total N 2 molecules experience dissociation. At wavelengths shorter than 66 nm, where the N 2 molecule experiences continuum photoabsorption (23), the photon flux is equal to the N 2 dissociation rates under our optically thick condition and is estimated to be 1-1.5× 10 16 photons∕s, which is consistent with previous measurement (24).…”
Section: Resultssupporting
confidence: 79%
“…At wavelengths shorter than 80 nm irradiation, approximately 3-5% of total N 2 molecules experience dissociation. At wavelengths shorter than 66 nm, where the N 2 molecule experiences continuum photoabsorption (23), the photon flux is equal to the N 2 dissociation rates under our optically thick condition and is estimated to be 1-1.5× 10 16 photons∕s, which is consistent with previous measurement (24).…”
Section: Resultssupporting
confidence: 79%
“…16 A schematic of the instrument is shown in Figure 1. Most of the experimental apparatus has been described in detail elsewhere.…”
Section: Methodsmentioning
confidence: 99%
“…At the Chemical Dynamics Beamline, an undulator provides ∼10 16 photons s -1 (2.5% bandwidth) of linearly polarized light from 7 to 30 eV. 31 Terminal 3 consists of a 3m off-plane Eagle monochromator fitted with a 600 lines/mm grating and a best possible energy resolution (E/∆E) ≈ 3000. For these experiments, an Ir-coated master grating blazed for 16 eV was used, and the monochromator was set to provide E/∆E ≈ 600, yielding 10 13 photons s -1 in the range of 20-26 eV.…”
Section: Methodsmentioning
confidence: 99%