2009
DOI: 10.1109/tpwrd.2008.2002959
|View full text |Cite
|
Sign up to set email alerts
|

Performance of the OVP/UVP and OFP/UFP Method With Voltage and Frequency Dependent Loads

Abstract: In previous literature, constant RLC loads were assumed to impose, on the islanding detection method, the hardest detectable case. For this reason, distributed-generation (DG) islanding studies are usually analyzed and performed by using constant RLC loads. In this paper, different types of loads are taken into account by modeling the load's voltage and frequency dependence. The performance of the over/undervoltage and over/underfrequency protection (OVP/UVP and OFP/UFP) method is examined for the different lo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
47
0
3

Year Published

2014
2014
2022
2022

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 112 publications
(50 citation statements)
references
References 5 publications
0
47
0
3
Order By: Relevance
“…Islanding detection methods can be divided into three main categories: communication based [5,6], active based [7][8][9][10][11][12][13][14][15], and passive based [16][17][18][19][20][21][22]. Communication based methods are very accurate but are the most expensive among islanding detection techniques.…”
Section: Literature Reviewmentioning
confidence: 99%
See 2 more Smart Citations
“…Islanding detection methods can be divided into three main categories: communication based [5,6], active based [7][8][9][10][11][12][13][14][15], and passive based [16][17][18][19][20][21][22]. Communication based methods are very accurate but are the most expensive among islanding detection techniques.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Over/Under Frequency islanding detection technique relies on the frequency at the PCC of the island to detect islanding [16,17,18]. As discussed earlier, frequency deviation depends on the mismatch in reactive power.…”
Section: Over/under Frequency and Rate Of Change Of Frequencymentioning
confidence: 99%
See 1 more Smart Citation
“…Ajustes típicos estão na faixa de 0,5-0,8 e 1,1-1,2 pu [11], e essa proteção pode ser utilizada para detecção do ilhamento, como apresentado em [46]; [72].…”
Section: Funções De Proteção 27/59unclassified
“…As conclusões para um sistema com GD síncrono mostram que cargas de impedância constante apresentam resultados mais conservadores da proteção anti-ilhamento baseada em medidas de frequência, para condições de operação de excesso de potência ativa e reativa, ou déficit de potência ativa e reativa [46].…”
Section: Variações Da Demanda Das Cargas No Sistema De Distribuiçãounclassified