2023
DOI: 10.1111/ijlh.14178
|View full text |Cite
|
Sign up to set email alerts
|

Performance of the new MC‐80 automated digital cell morphology analyser in detection of normal and abnormal blood cells: Comparison with the CellaVision DM9600

Anna Merino,
Javier Laguna,
María Rodríguez‐García
et al.

Abstract: IntroductionMindray MC‐80 is an automated system for digital imaging of white blood cells (WBCs) and their pre‐classification. The objective of this work is to analyse its performance comparing it with the CellaVision® DM9600.MethodsA total of 445 samples were used, 194 normal and 251 abnormal: acute leukaemia (100), myelodysplastic syndromes/myeloproliferative neoplasms (33), lymphoid neoplasms (50), plasma cell neoplasms (14), infections (49) and thrombocytopenia (5). WBC pre‐classification values with the M… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 53 publications
0
2
0
Order By: Relevance
“…Our study has several limitations. Firstly, in other comparative studies using different brands of DM analyzers, 14,15 was not an intentional omission, but rather a consequence of the lack of adult ALL cases in our institute. Additionally, only 100 PB smears were collected for performance evaluation, and the number of some abnormal cells, such as reactive lymphocytes, promyelocytes, and plasma cells, was relatively small.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Our study has several limitations. Firstly, in other comparative studies using different brands of DM analyzers, 14,15 was not an intentional omission, but rather a consequence of the lack of adult ALL cases in our institute. Additionally, only 100 PB smears were collected for performance evaluation, and the number of some abnormal cells, such as reactive lymphocytes, promyelocytes, and plasma cells, was relatively small.…”
Section: Discussionmentioning
confidence: 99%
“…10 As a DM analyzer launched in China, the MC-80 has exhibited excellent performance in leukocyte morphology analysis, as indicated by several independent studies. 11,12 There is a growing trend in comparing the performance of different brands of DM analyzers, such as CellaVision DC-1 versus Sysmex DI-60, 13 Mindray MC-80 versus Cel-laVision DM 9600, 14 and Mindray MC-100i versus Sysmex DI-60. 15 CellaVision has developed a series of automated morphological analysis systems, including the DM96, DM1200, and DM 9600.…”
Section: Introductionmentioning
confidence: 99%