2018
DOI: 10.1002/ccd.27588
|View full text |Cite
|
Sign up to set email alerts
|

Performance of the Evolut‐R 34 mm versus Sapien‐3 29 mm in Transcatheter aortic valve replacement patients with larger annuli: Early outcome results of Evolut‐R 34 mm as compared with Sapien‐3 29 mm in patients with Annuli ≥26 mm

Abstract: As compared to Sapien-3 29 mm the Evolut-R 34 mm is a real alternative for TAVR in patients with a large annulus with a comparable peri-procedural complication rate, better hemodynamic results but a trend for higher pacemaker rate.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
19
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 29 publications
(20 citation statements)
references
References 15 publications
(21 reference statements)
1
19
0
Order By: Relevance
“…Another study (16) examined gender-based differences in outcomes, in a cohort of Evolut R and Sapien 3 TAVI patients without any comparison between the 2 valves. A total of 5 studies (8,1720) met the inclusion criteria and were included in the systematic review and meta-analysis. No randomized controlled trials were available for inclusion.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Another study (16) examined gender-based differences in outcomes, in a cohort of Evolut R and Sapien 3 TAVI patients without any comparison between the 2 valves. A total of 5 studies (8,1720) met the inclusion criteria and were included in the systematic review and meta-analysis. No randomized controlled trials were available for inclusion.…”
Section: Resultsmentioning
confidence: 99%
“…Four (8,1820) were retrospective cohort studies, while one was a prospective study (17). The prospective study (17) compared outcomes between Evolut R and Sapien 3 valves in patients with large annuli (≥26 mm). None of the remaining studies used any exclusion criteria based on any patient characteristic.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Small series from local registries have been recently published showing comparable success and complication rates for the novel 34 mm Evolut R valve compared to the smaller Evolut R prostheses . A small recent non‐randomized study compared the new Evolut R 34 mm device with the balloon expandable Sapien‐3 29 mm for patients with aortic annuli bigger than 26 mm showing comparable periprocedural complication rates . However, to date, there are no data comparing the novel self‐expandable device with its 31 mm predecessor.…”
Section: Introductionmentioning
confidence: 99%
“…The need for postprocedural PPI was significantly enhanced in HA using a 34 mm device size. A higher incidence of PPI was already described in the large new‐generation TAVR device 18 and is also frequently experienced in dependency from calcification burden and implantation depth 19 . However, the large system failed to be a dependent or independent predictor for PPI, whereas a valve size of 26 mm was highly preventive for PPI need.…”
Section: Discussionmentioning
confidence: 90%