1998
DOI: 10.1086/316126
|View full text |Cite
|
Sign up to set email alerts
|

Performance of the Canada‐France‐Hawaii Telescope Adaptive Optics Bonnette

Abstract: Extensive results from the commissioning phase of PUEO, the adaptive optics instrument adaptor for the Canada-France-Hawaii telescope (CFHT), are presented and discussed. Analyses of more than 750 images recorded with a CCD and a near-IR camera on 16 nights in wavelengths from B to H are used to derive the properties of the compensated wavefront and images in a variety of conditions. The performance characteristics of the system are analyzed and presented in several ways, in terms of delivered Strehl ratios, f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
96
0

Year Published

2000
2000
2023
2023

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 145 publications
(100 citation statements)
references
References 22 publications
3
96
0
Order By: Relevance
“…HD 14348 and HD 18757 were observed as filler targets during a program dedicated to mass measurements for M dwarfs at the 3.6 m Canada-France-Hawaii Telescope (CFHT) using PUEO, the CFHT Adaptive Optics Bonnette (Rigaut et al 1998), and the KIR infrared camera (Doyon et al 1998). The observing procedure is described by Delfosse et al (1999).…”
Section: High-resolution Imaging With Pueomentioning
confidence: 99%
“…HD 14348 and HD 18757 were observed as filler targets during a program dedicated to mass measurements for M dwarfs at the 3.6 m Canada-France-Hawaii Telescope (CFHT) using PUEO, the CFHT Adaptive Optics Bonnette (Rigaut et al 1998), and the KIR infrared camera (Doyon et al 1998). The observing procedure is described by Delfosse et al (1999).…”
Section: High-resolution Imaging With Pueomentioning
confidence: 99%
“…We observed θ Cygni at high angular resolution and high contrast with the adaptive-optics (AO) instrument PUEO (Rigaut et al 1998) mounted on the 3.6-m Canada-France-Hawaii Telescope (CFHT, USA). The near-infrared camera used, KIR (Doyon et al 1998), has a field of view of ∼35 × 35 , with a scale of ∼0.035 per pixel.…”
Section: Imaging Datamentioning
confidence: 99%
“…We used the MR3 configuration covering the Ca triplet (8500Å) region. This configuration was favoured above the classical Mg2 (5200Å) wavelength range because PUEO, like all other adaptive optics systems, performs better at longer wavelength (Rigaut et al 1998). The selected spatial sampling of 0.…”
Section: Observationsmentioning
confidence: 99%