2020
DOI: 10.1007/s10008-020-04512-6
|View full text |Cite
|
Sign up to set email alerts
|

Performance of Ni/10Sc1CeSZ anode synthesized by glycine nitrate process assisted by microwave heating in a solid oxide fuel cell fueled with hydrogen or methane

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 52 publications
1
11
0
Order By: Relevance
“…A previous study synthesized Ni/10Sc1CeSZ anode using GNP assisted by a uniform microwave heating technique. The results showed improvements in the performance due to the improvement in the morphology of the cermet powder 166 ; such improvement is a result of the uniform heating by the microwave energy.…”
Section: Wet Chemical Methodsmentioning
confidence: 98%
“…A previous study synthesized Ni/10Sc1CeSZ anode using GNP assisted by a uniform microwave heating technique. The results showed improvements in the performance due to the improvement in the morphology of the cermet powder 166 ; such improvement is a result of the uniform heating by the microwave energy.…”
Section: Wet Chemical Methodsmentioning
confidence: 98%
“…All chemical reagents were analytical grade and supplied by Aladdin company. [37][38][39][40][41] La(NO 3 ) 3 ⋅6H 2 O and Fe(NO 3 ) 3 ⋅9H 2 O (each of 0.02 mol, La/Fe = 1:1) were dissolved in 200 mL of deionized water under stirring. Afterward, 7.5 g of glycine (glycine-to-nitrate molar ratio of 2.5) was added.…”
Section: Methodsmentioning
confidence: 99%
“…The electrical conductivity of the prepared LCXO/BCZY/LCXO symmetrical cells were tested under a flow of dry air at the rate of 100 mL/min. Conductivity was measured via the four‐point van der Pauw method described in 26,27 . Button‐shaped symmetrical cells were placed onto a homemade sample holder equipped with platinum wires attached through four probes.…”
Section: Methodsmentioning
confidence: 99%
“…Conductivity was measured via the four-point van der Pauw method described in. 26,27 Button-shaped symmetrical cells were placed onto a homemade sample holder equipped with platinum wires attached through four probes. The electrical conductivity of the cathodes was recorded starting from the operating temperature of 700 C up to 500 C. The electrical conductivity and activation energy of each cathode were then calculated.…”
Section: Electrical Conductivity Measurementsmentioning
confidence: 99%