2006
DOI: 10.1039/b511505c
|View full text |Cite
|
Sign up to set email alerts
|

Performance of methods for measurement of exposure to inorganic acids in workplace air

Abstract: BGIA has organised round robins for the analysis of samples of inorganic acids in workplace air for a number of years. Test samples of the volatile acids HCl and HNO(3) are collected from a standard atmosphere and samples of the non-volatile acids H(3)PO(4) and H(2)SO(4) are prepared by spiking filters with acid solution. The last two round robins have also covered the sampling of volatile acids, with up to 15 "active" participants able to visit the test facility in Dresden and take samples themselves. For oth… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0

Year Published

2008
2008
2015
2015

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 7 publications
(15 citation statements)
references
References 1 publication
0
15
0
Order By: Relevance
“…(7) To check if this type of reaction can also occur with acids having approximately the same strength, a final interference experiment was designed using, as a prefilter, a quartz fiber filter impregnated with either 10 mg sodium chloride (NaCl) or sodium nitrate (NaNO 3 ), and sampling the acid corresponding to the other salt through this filter. This particular mass of salt was chosen to simulate a filter having collected dust at one 8 hr-LV of low toxicity inhalable dust.…”
Section: Salt Interferencesmentioning
confidence: 99%
See 1 more Smart Citation
“…(7) To check if this type of reaction can also occur with acids having approximately the same strength, a final interference experiment was designed using, as a prefilter, a quartz fiber filter impregnated with either 10 mg sodium chloride (NaCl) or sodium nitrate (NaNO 3 ), and sampling the acid corresponding to the other salt through this filter. This particular mass of salt was chosen to simulate a filter having collected dust at one 8 hr-LV of low toxicity inhalable dust.…”
Section: Salt Interferencesmentioning
confidence: 99%
“…After preliminary work published in 2006, (7) the International Standards Organization (ISO) published a three-part standard (ISO 21438) (8)(9)(10) on the determination of inorganic acids in workplace air by ion chromatography (IC). During the development of Part 2 of the standard (ISO 21438-2), (9) which describes the alkali-impregnated filter method for volatile acids (except hydrofluoric acid), a series of sampling exercises were carried out by several European institutes at the test gas facility of the Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA) in Sankt Augustin, Germany, to characterize the performance of existing methods for sampling HCl and HNO 3 .…”
mentioning
confidence: 99%
“…(17,18) Estimated MDLs for H 2 SO 4 and H 3 PO 4 were 0.002 mg/m 3 and 0.003 mg/m 3 for a sampled air volume of 1 m 3 . Expanded measurement uncertainty obtained for both acids was <23%.…”
Section: Niosh Methods 7908 For Non-volatile Acids: Sulfuric and Phospmentioning
confidence: 97%
“…An interlaboratory study with 26 participants found negligible biases and interlaboratory relative standard deviations of 12–15% for H 2 SO 4 and H 3 PO 4 concentrations between 0.05 and 1 mg/m 3. (17) The method has also been successfully field tested for workplace H 2 SO 4 measurements at sample volumes of up to nearly 2,000 liters. (18) …”
Section: Niosh Methods 7908 For Non-volatile Acids: Sulfuric and Phospmentioning
confidence: 99%
“…6 Sampling of aerosols containing SV compounds using methods like lter sampling can prove to be challenging. [7][8][9] The particles trapped on lters can readily evaporate [10][11][12] or vapours can adsorb 13 on ltration substrates, thus leading to measurement errors as a consequence.…”
Section: Introductionmentioning
confidence: 99%