2018
DOI: 10.1007/s40999-018-0366-0
|View full text |Cite
|
Sign up to set email alerts
|

Performance of Loop Connection in Precast Concrete Walls Subjected to Lateral Loads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 20 publications
0
7
0
Order By: Relevance
“…This system has a hole that fits in a corresponding anchor bolt, then the walls are attached using nuts and washers. Taheri et al (2016) and Vaghei et al (2019) studied a connection composed by male-female panels, rubber, hooks, bolts and nut (Figure 17(e)). This system was an improvement of the loop connection (wet connection) and the results showed a significant increase of the maximum strength (Biswal et al, 2019).…”
Section: Precast Walls Connectionsmentioning
confidence: 99%
See 2 more Smart Citations
“…This system has a hole that fits in a corresponding anchor bolt, then the walls are attached using nuts and washers. Taheri et al (2016) and Vaghei et al (2019) studied a connection composed by male-female panels, rubber, hooks, bolts and nut (Figure 17(e)). This system was an improvement of the loop connection (wet connection) and the results showed a significant increase of the maximum strength (Biswal et al, 2019).…”
Section: Precast Walls Connectionsmentioning
confidence: 99%
“…Finally, here is also an H-connector with steel bolts that was studied to link precast walls and showed a satisfactory performance under monotonic and cyclic loading (Sun et al, 2019) (Figure 17(f)).
Figure 17.Examples of dry connections (collected/adapted from literature review: (a) Brunesi and Nascimbene, 2017; (b) Cai et al, 2019; (c) Guo et al, 2019; (d) Psycharis et al, 2018; (e) Taheri et al, 2016 and Vaghei et al, 2019; (f) Sun et al, 2019.
…”
Section: Precast Walls Connectionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Table 2 summarized the findings of three (3) out of ten (10) papers that have been reviewed and discussed wire ropes connection in terms of embedded length, bonding stress and modes of failure. [14].…”
Section: B Wire Ropes Connectionmentioning
confidence: 99%
“…Several connection systems for vertical joints have been recommended by researchers across the globe such as U-bars, O-connectors [12], steel plates and anchors [13] and U-shaped channel and rubber [14]. Table 1 summarizes different connection systems for precast RC panels and their behaviour under lateral loading.…”
Section: Introductionmentioning
confidence: 99%