Performance of Depressurization Devices to Dynamic Loads Generated by Arcing in Liquid Filled Transformers

Abstract: This study provides a methodology that can be used to evaluate the dynamic performance of fast depressurization devices used in liquid-filled oil transformers. Liquid-filled transformers are susceptible to explosions due to internal arcing if the dielectric insulation fails. The internal arc vaporizes a portion of the liquid and generates a sudden pressure wave. The first peak of the pressure wave has been measured to be as high as 13 bars, with time durations on the order of milliseconds [1]. Transformer tank… Show more